Active Carbonic Anhydrase III, Muscle Specific (CA3)
CA-III; CAIII; Car3; Carbonate dehydratase III
- Product No.APD070Hu01
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Buffer FormulationPBS, pH7.4, containing 0.01% SKL, 5% Trehalose.
- Traits Freeze-dried powder
- Purity> 90%
- Isoelectric Point7.4
- ApplicationsCell culture; Activity Assays.
- DownloadInstruction Manual
- UOM 10µg50µg 200µg 1mg 5mg
- FOB
US$ 136
For more details, please contact local distributors! US$ 340 US$ 680 US$ 2040 US$ 5100
ACTIVITY TEST
Carbonic Anhydrase (CA) catalyzes the reversible reaction of CO2 H2O = HCO3- H , which is fundamental to many processes such as respiration, renal tubular acidification and bone resorption. CA3 is a cytosolic enzyme with a very low CA activity. It is expressed at low levels in human muscle during early development but increases rapidly during the last trimester to reach 50-60% of adult levels at birth. The activity of recombinant human CA3 was measured by its ability to hydrolyze 4-Nitrophenyl acetate (4-NPA) to 4-Nitrophenol. The reaction was performed in 12.5 mM Tris, 75 mM NaCl, pH 7.5 (assay buffer), initiated by addition 50 μL of various concentrations of CA3 (diluted by assay buffer) to 50 µL of 2 mM substrate 4-NPA (100 mM stock in Acetone, diluted by assay buffer). Incubated at 37℃ for 5min, then read at a wavelength of 400 nm.
USAGE
Reconstitute in 10mM PBS (pH7.4) to a concentration of 0.1-1.0 mg/mL. Do not vortex.
STORAGE
Avoid repeated freeze/thaw cycles. Store at 2-8°C for one month. Aliquot and store at -80°C for 12 months.
STABILITY
The thermal stability is described by the loss rate. The loss rate was determined by accelerated thermal degradation test, that is, incubate the protein at 37°C for 48h, and no obvious degradation and precipitation were observed. The loss rate is less than 5% within the expiration date under appropriate storage condition.
GIVEAWAYS
INCREMENT SERVICES
- BCA Protein Quantification Kit
- Molecular Mass Marker for Protein
- Monoclonal Antibody Customized Service
- Polyclonal Antibody Customized Service
- Protein Activity Test Experiment Service
- Electrophoretic Mobility Shift Assay (EMSA) Experiment Service
- Buffer
- Lentivirus Packaging Experiment Service
- Adenovirus Packaging Experiment Service
- Real Time PCR Experimental Service
- Spike RBD Protein (S-RBD)
- Protein G
- Protein A
Magazine | Citations |
Biomarkers in Medicine | Biochemical markers of muscle damage and high serum concentration of creatine kinase in patients on statin therapy Pubmed: 31157560 |