CLIA Kit for Secondary Lymphoid Tissue Chemokine (SLC)

CCL21; 6Ckine; CKb9; ECL; SCYA21; TCA4; ECL; Chemokine(C-C-Motif)Ligand 21; Beta Chemokine Exodus-2; Efficient Chemoattractant For Lymphocytes

Specificity

This assay has high sensitivity and excellent specificity for detection of Secondary Lymphoid Tissue Chemokine (SLC).
No significant cross-reactivity or interference between Secondary Lymphoid Tissue Chemokine (SLC) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Secondary Lymphoid Tissue Chemokine (SLC) and the recovery rates were calculated by comparing the measured value to the expected amount of Secondary Lymphoid Tissue Chemokine (SLC) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 87-95 90
EDTA plasma(n=5) 92-101 95
heparin plasma(n=5) 90-104 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Secondary Lymphoid Tissue Chemokine (SLC) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Secondary Lymphoid Tissue Chemokine (SLC) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Secondary Lymphoid Tissue Chemokine (SLC) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-101% 86-94% 91-98% 91-99%
EDTA plasma(n=5) 79-95% 95-103% 78-99% 89-99%
heparin plasma(n=5) 89-103% 89-96% 78-93% 92-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
Substrate A 1×10mL Substrate B 1×2mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
类风湿关节炎血清中CCL19 和CCL21 的表达水平与肺间质病变的关系 :
Behavioural Brain Research Dysregulation of miR-142 results in anxiety-like behaviors following single prolonged stress Pubmed: 30857769
Neuroscience Letters Sigma-1 receptor activation ameliorates LPS-induced NO production and ROS formation through the Nrf2/HO-1 signaling pathway in cultured astrocytes Pubmed: 31330223
Cell Mol Neurobiol miR-132 Regulates PTSD-like Behaviors in Rats Following Single-Prolonged Stress Through Fragile X-Related Protein 1 Pubmed: 32333305
J Neuroinflammation miR-142 downregulation alleviates rat PTSD-like behaviors, reduces the level of inflammatory cytokine expression and apoptosis in hippocampus, and?¡­ 33407653
Exp Neurol MiR-153 downregulation alleviates PTSD-like behaviors and reduces cell apoptosis by upregulating the Sigma-1 receptor in the hippocampus of rats exposed to … Pubmed:35259352
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APB575Hu01 Active Secondary Lymphoid Tissue Chemokine (SLC) Cell culture; Activity Assays.
RPB575Hu01 Recombinant Secondary Lymphoid Tissue Chemokine (SLC) Positive Control; Immunogen; SDS-PAGE; WB.
PAB575Hu01 Polyclonal Antibody to Secondary Lymphoid Tissue Chemokine (SLC) WB; IHC; ICC; IP.
LAB575Hu71 Biotin-Linked Polyclonal Antibody to Secondary Lymphoid Tissue Chemokine (SLC) WB; IHC; ICC.
MAB575Hu22 Monoclonal Antibody to Secondary Lymphoid Tissue Chemokine (SLC) WB; IHC; ICC; IP.
SEB575Hu ELISA Kit for Secondary Lymphoid Tissue Chemokine (SLC) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB575Hu CLIA Kit for Secondary Lymphoid Tissue Chemokine (SLC) Chemiluminescent immunoassay for Antigen Detection.
LMB575Hu Multiplex Assay Kit for Secondary Lymphoid Tissue Chemokine (SLC) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.