Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Karyopherin Alpha 2 (KPNa2) ,etc. by FLIA (Flow Luminescence Immunoassay)
IPOA1; QIP2; RCH1; SRP1alpha; RAG Cohort 1; Importin Alpha 1; RAG cohort protein 1; SRP1-alpha
(Note: Up to 8-plex in one testing reaction)
- Product No.LME748Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeTissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range7.81-8000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 2.603 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 437
US$ 454
US$ 479
US$ 512
US$ 546
US$ 596
US$ 672
Result
For more details, please contact local distributors! US$ 840 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Karyopherin Alpha 2 (KPNa2) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Karyopherin Alpha 2 (KPNa2) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Karyopherin Alpha 2 (KPNa2) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Karyopherin Alpha 2 (KPNa2) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 89-103 | 99 |
EDTA plasma(n=5) | 89-99 | 95 |
heparin plasma(n=5) | 84-99 | 94 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Karyopherin Alpha 2 (KPNa2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Karyopherin Alpha 2 (KPNa2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Karyopherin Alpha 2 (KPNa2) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 87-103% | 86-101% | 85-94% | 90-99% |
EDTA plasma(n=5) | 93-105% | 85-99% | 80-102% | 99-105% |
heparin plasma(n=5) | 91-99% | 89-101% | 80-93% | 97-104% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:KPNa2) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Oncol Rep.? | KPNA2 is a promising biomarker candidate for esophageal squamous cell carcinoma and correlates with cell proliferation Pubmed:25109899 |
Tumor Biology | KPNA2 is a potential diagnostic serum biomarker for epithelial ovarian cancer and correlates with poor prognosis pubmed:28651492 |
Head & Neck | Association of overexpressed karyopherin alpha 2 with poor survival and its contribution to interleukin‐1β‐induced matrix metalloproteinase expression in oral cancer Pubmed:29542209 |
International Journal of Cancer | Nuclear transport proteins are secreted by cancer cells and identified as potential novel cancer biomarkers 34591985 |