Multiplex Assay Kit for Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay)

AT3; ATIII; SERPINC1; Anti-Thrombin Antibodies; Serpin Peptidase Inhibitor Clade C Member 1; Coding Sequence Signal Peptide Antithrombin Part 1

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-101 86
EDTA plasma(n=5) 96-105 101
heparin plasma(n=5) 99-105 102
sodium citrate plasma(n=5) 96-103 99

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-102% 88-102% 82-101% 80-90%
EDTA plasma(n=5) 98-105% 92-105% 91-99% 84-96%
heparin plasma(n=5) 98-105% 87-101% 81-92% 90-97%
sodium citrate plasma(n=5) 98-105% 98-105% 98-105% 81-91%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:AT) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Thromb Res Thalidomide and multiple myeloma serum synergistically induce a hemostatic imbalance in endothelial cells in vitro PubMed: 25840743
Neurotherapeutics iTRAQ-Based Quantitative Proteomics Reveals the New Evidence Base for Traumatic Brain Injury Treated with Targeted Temperature Management pubmed:29247448
Journal of Clinical and Aesthetic Dermatology Detection of Angiotensin II and AT1 Receptor Concentrations in Keloid and Hypertrophic Scar.
博士论文 An Agile Approach to Novel Recombinant Antithrombin Production for use in Biologics Development
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
NPC313Hu01 Native Antithrombin (AT) Positive Control; Immunogen; SDS-PAGE; WB.
APC313Hu01 Active Antithrombin (AT) Cell culture; Activity Assays.
RPC313Hu03 Recombinant Antithrombin (AT) Positive Control; Immunogen; SDS-PAGE; WB.
EPC313Hu61 Eukaryotic Antithrombin (AT) Positive Control; Immunogen; SDS-PAGE; WB.
RPC313Hu01 Recombinant Antithrombin (AT) Positive Control; Immunogen; SDS-PAGE; WB.
RPC313Hu02 Recombinant Antithrombin (AT) Positive Control; Immunogen; SDS-PAGE; WB.
APC313Hu61 Active Antithrombin (AT) Cell culture; Activity Assays.
PAC313Hu01 Polyclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
PAC313Hu02 Polyclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
PAC313Hu03 Polyclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
LAC313Hu81 FITC-Linked Polyclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IF.
LAC313Hu71 Biotin-Linked Polyclonal Antibody to Antithrombin (AT) WB; IHC; ICC.
MAC313Hu21 Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
MAC313Hu27 Monoclonal Antibody to Antithrombin (AT) WB,IHC
MAC313Hu29 Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
MAC313Hu23 Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
MAC313Hu24 Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
MAC313Hu26 Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
MAC313Hu22 Monoclonal Antibody to Antithrombin (AT) WB,IHC
MAC313Hu28 Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
MAC313Hu25 Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IP.
FAC313Hu02 Anti-Antithrombin (AT) Monoclonal Antibody FCM
FAC313Hu04 Anti-Antithrombin (AT) Monoclonal Antibody FCM
FAC313Hu08 Anti-Antithrombin (AT) Monoclonal Antibody FCM
LAC313Hu72 Biotin-Linked Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC.
LAC313Hu82 FITC-Linked Monoclonal Antibody to Antithrombin (AT) WB; IHC; ICC; IF.
SEC313Hu ELISA Kit for Antithrombin (AT) Enzyme-linked immunosorbent assay for Antigen Detection.
SCC313Hu CLIA Kit for Antithrombin (AT) Chemiluminescent immunoassay for Antigen Detection.
LMC313Hu Multiplex Assay Kit for Antithrombin (AT) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSC313Hu01 ELISA Kit DIY Materials for Antithrombin (AT) Main materials for "Do It (ELISA Kit) Yourself".