Multiplex Assay Kit for Nephrin (NPHN) ,etc. by FLIA (Flow Luminescence Immunoassay)

NPHS1; CNF; Nephrosis 1; Congenital Finnish Type; Renal glomerulus-specific cell adhesion receptor

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Nephrin (NPHN) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Nephrin (NPHN) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Nephrin (NPHN) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Nephrin (NPHN) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 96-104 101
EDTA plasma(n=5) 93-104 96
heparin plasma(n=5) 87-96 90

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Nephrin (NPHN) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Nephrin (NPHN) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Nephrin (NPHN) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 87-104% 83-98% 89-98%
EDTA plasma(n=5) 84-101% 80-98% 87-104% 87-101%
heparin plasma(n=5) 94-105% 98-105% 80-98% 93-102%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:NPHN) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Yonsei medical journal The Level of Serum and Urinary Nephrin in Normal Pregnancy and Pregnancy with Subsequent Preeclampsia. pubmed:28120572
Experimental and molecular pathology Alteration of Connexin43 expression in a rat model of obesity-related glomerulopathy. pubmed:29246788
British Journal of Haematology  Renal protection by atorvastatin in a murine model of sickle cell nephropathy Pubmed:29527679
Journal of Clinical Medicine Multiplex Bead Array Assay of a Panel of Circulating Cytokines and Growth Factors in Patients with Albuminuric and Non-AlbuminuricDiabetic Kidney Disease Pubmed: 32961903
Disease Markers Urinary Matrix Metalloproteinase-9 and Nephrin in Idiopathic Membranous Nephropathy: A Cross-Sectional Study 34707724
Biomed Rep Early biomarkers of nephrotoxicity associated with the use of anti-VEGF drugs Pubmed:35620307
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPA937Ra01 Recombinant Nephrin (NPHN) Positive Control; Immunogen; SDS-PAGE; WB.
PAA937Ra01 Polyclonal Antibody to Nephrin (NPHN) WB; IHC; ICC; IP.
MAA937Ra21 Monoclonal Antibody to Nephrin (NPHN) WB; IHC; ICC; IP.
SEA937Ra ELISA Kit for Nephrin (NPHN) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA937Ra Multiplex Assay Kit for Nephrin (NPHN) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA937Ra01 ELISA Kit DIY Materials for Nephrin (NPHN) Main materials for "Do It (ELISA Kit) Yourself".