Multiplex Assay Kit for Colony Stimulating Factor 1, Macrophage (MCSF) ,etc. by CBA (Cytometric Bead Array)

CSF1; M-CSF; Lanimostim; Processed macrophage colony-stimulating factor 1

Specificity

This assay has high sensitivity and excellent specificity for detection of Colony Stimulating Factor 1, Macrophage (MCSF) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Colony Stimulating Factor 1, Macrophage (MCSF) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Colony Stimulating Factor 1, Macrophage (MCSF) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Colony Stimulating Factor 1, Macrophage (MCSF) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-103 82
EDTA plasma(n=5) 82-95 89
heparin plasma(n=5) 83-105 90

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Colony Stimulating Factor 1, Macrophage (MCSF) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Colony Stimulating Factor 1, Macrophage (MCSF) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Colony Stimulating Factor 1, Macrophage (MCSF) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 93-105% 79-99% 85-98% 93-101%
EDTA plasma(n=5) 87-98% 94-105% 85-94% 78-90%
heparin plasma(n=5) 94-101% 79-95% 91-101% 83-92%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Brain Pathology Microglia-Derived Macrophage Colony Stimulating Factor Promotes Generation of Proinflammatory Cytokines by Astrocytes in the Periventricular White Matter in the Hypoxic Neonatal Brain Wiley: source
Oncotarget miR-1207-5p suppresses lung cancer growth and metastasis by targeting CSF1 pubmed:27107415
bulletin of experimental biology and medicine Quantitative and Qualitative Characterization of Phagocytic Activity of Macrophages of Bone Marrow and Fetal Origin Pubmed: 31183654
BioMed Research International Ultrashort Wave Combined with Human Umbilical Cord Mesenchymal Stem Cell (HUC-MSC) Transplantation Inhibits NLRP3 Inflammasome and Improves?¡­ 33376718
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA090Hu01 Recombinant Colony Stimulating Factor 1, Macrophage (MCSF) Positive Control; Immunogen; SDS-PAGE; WB.
EPA090Hu63 Eukaryotic Colony Stimulating Factor 1, Macrophage (MCSF) Positive Control; Immunogen; SDS-PAGE; WB.
RPA090Hu02 Recombinant Colony Stimulating Factor 1, Macrophage (MCSF) Positive Control; Immunogen; SDS-PAGE; WB.
APA090Hu02 Active Colony Stimulating Factor 1, Macrophage (MCSF) Cell culture; Activity Assays.
EPA090Hu61 Eukaryotic Colony Stimulating Factor 1, Macrophage (MCSF) Positive Control; Immunogen; SDS-PAGE; WB.
APA090Hu62 Active Colony Stimulating Factor 1, Macrophage (MCSF) Cell culture; Activity Assays.
APA090Hu63 Active Colony Stimulating Factor 1, Macrophage (MCSF) Cell culture; Activity Assays.
EPA090Hu62 Eukaryotic Colony Stimulating Factor 1, Macrophage (MCSF) Positive Control; Immunogen; SDS-PAGE; WB.
APA090Hu01 Active Colony Stimulating Factor 1, Macrophage (MCSF) Cell culture; Activity Assays.
PAA090Hu01 Polyclonal Antibody to Colony Stimulating Factor 1, Macrophage (MCSF) WB
MAA090Hu22 Monoclonal Antibody to Colony Stimulating Factor 1, Macrophage (MCSF) WB
MAA090Hu21 Monoclonal Antibody to Colony Stimulating Factor 1, Macrophage (MCSF) WB
MEA090Hu Mini Samples ELISA Kit for Colony Stimulating Factor 1, Macrophage (MCSF) Enzyme-linked immunosorbent assay for Antigen Detection.
SEA090Hu ELISA Kit for Colony Stimulating Factor 1, Macrophage (MCSF) Enzyme-linked immunosorbent assay for Antigen Detection.
CMA090Hu Multiplex Assay Kit for Colony Stimulating Factor 1, Macrophage (MCSF) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMA090Hu Multiplex Assay Kit for Colony Stimulating Factor 1, Macrophage (MCSF) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.