ELISA Kit for Interleukin 8 Receptor Beta (IL8Rb)

CD182; CDw128b; IL8R-B; IL8-RB; CMKAR2; CXCR2; IL8R2; C-X-C chemokine receptor type 2; GRO/MGSA receptor; High affinity interleukin-8 receptor B

Specificity

This assay has high sensitivity and excellent specificity for detection of Interleukin 8 Receptor Beta (IL8Rb).
No significant cross-reactivity or interference between Interleukin 8 Receptor Beta (IL8Rb) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Interleukin 8 Receptor Beta (IL8Rb) and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 8 Receptor Beta (IL8Rb) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 86-95 91
EDTA plasma(n=5) 86-101 96
heparin plasma(n=5) 87-94 90

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 8 Receptor Beta (IL8Rb) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 8 Receptor Beta (IL8Rb) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 8 Receptor Beta (IL8Rb) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-88% 85-101% 98-105% 83-91%
EDTA plasma(n=5) 88-97% 86-103% 92-105% 92-105%
heparin plasma(n=5) 95-105% 93-101% 94-103% 85-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Theranostics Direct Macromolecular Drug Delivery to Cerebral Ischemia Area using Neutrophil-Mediated Nanoparticles. pubmed:28900508
Scientific Reports Role of ceramide synthase 2 in G-CSF signaling and G-CSF-R translocation into detergent-resistant membranes Pubmed: 30679689
Pathogenic Functions of Tumor Necrosis Factor Receptor-associated Factor 6 Signaling following Traumatic Brain Injury
The neuroprotection of hyperbaric oxygen therapy against traumatic brain injury via NF-¦ÊB/MAPKs-CXCL1 signaling pathway
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPC006Mu02 Recombinant Interleukin 8 Receptor Beta (IL8Rb) Positive Control; Immunogen; SDS-PAGE; WB.
RPC006Mu01 Recombinant Interleukin 8 Receptor Beta (IL8Rb) Positive Control; Immunogen; SDS-PAGE; WB.
SPC006Mu01 Synthetic Interleukin 8 Receptor Beta (IL8Rb) Immunogen; Blocking Peptide.
CPC006Mu21 OVA Conjugated Interleukin 8 Receptor Beta (IL8Rb) Immunogen; SDS-PAGE; WB.
PAC006Mu01 Polyclonal Antibody to Interleukin 8 Receptor Beta (IL8Rb) WB; IHC; ICC; IP.
PAC006Mu08 Polyclonal Antibody to Interleukin 8 Receptor Beta (IL8Rb) WB; IHC; ICC; IP.
PAC006Mu02 Polyclonal Antibody to Interleukin 8 Receptor Beta (IL8Rb) WB; IHC; ICC; IP.
SEC006Mu ELISA Kit for Interleukin 8 Receptor Beta (IL8Rb) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC006Mu Multiplex Assay Kit for Interleukin 8 Receptor Beta (IL8Rb) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.