ELISA Kit for Hemojuvelin (HJV)
HFE2; HFE2A; HJV; JH; RGMC; hemochromatosis type 2(Juvenile); Haemojuvelin; RGM domain family member C
- Product No.SEB995Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range31.25-2000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 14.3pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 461
For more details, please contact local distributors! US$ 658 US$ 2961 US$ 5593 US$ 46060
Specificity
This assay has high sensitivity and excellent specificity for detection of Hemojuvelin (HJV).
No significant cross-reactivity or interference between Hemojuvelin (HJV) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Hemojuvelin (HJV) and the recovery rates were calculated by comparing the measured value to the expected amount of Hemojuvelin (HJV) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 98-105 | 102 |
EDTA plasma(n=5) | 91-98 | 94 |
heparin plasma(n=5) | 83-97 | 86 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Hemojuvelin (HJV) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Hemojuvelin (HJV) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Hemojuvelin (HJV) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 80-103% | 78-102% | 78-97% | 81-92% |
EDTA plasma(n=5) | 83-94% | 92-102% | 88-102% | 94-102% |
heparin plasma(n=5) | 96-103% | 79-94% | 78-97% | 91-103% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- ELISA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Magazine | Citations |
PLoS One. | Effect of Iron Overload and Iron Deficiency on Liver Hemojuvelin Protein PubMed: PMC3356351 |
Journal of | Hepcidin Levels Are Increased in Patients with Acute Ischemic Stroke: Preliminary Report PubMed: 25881778 |
European Journal of Haematology | Soluble hemojuvelin in transfused and untransfused thalassaemic subjects doi:10.1111 |
American Journal of Nephrology | The secret war against counterfeit science pubmed:28492262 |
Critical Care | Urinary biomarkers predict advanced acute kidney injury after cardiovascular surgery Pubmed:29699579 |
Scientific Reports | Hemojuvelin Predicts Acute Kidney Injury and Poor Outcomes Following Cardiac Surgery Pubmed:29386545 |
Journal of Cerebral Blood Flow and Metabolism | The functional role of hemojuvelin in acute ischemic stroke Pubmed: 31307288 |
Oxidative damage and iron dyshomeostasis in thalassemic patients | |
J Trace Elem Med Biol | Caffeine and alcohol-friends or foes of human iron stores? Pubmed:35063815 |
Arch Pathol Lab Med | Urinary Biomarkers Can Predict Weaning From Acute Dialysis Therapy in Critically Ill Patients Pubmed:35311928 |
Arch Pathol Lab Med | The Relationships among Plasma Fetuin-B, Thyroid Autoimmunity, and Fertilization Rate In Vitro Fertilization and Embryo Transfer Pubmed:35340679 |
Catalog No. | Related products for research use of Rattus norvegicus (Rat) Organism species | Applications (RESEARCH USE ONLY!) |
RPB995Ra01 | Recombinant Hemojuvelin (HJV) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB995Ra01 | Polyclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC; IP. |
MAB995Ra21 | Monoclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC; IP. |
SEB995Ra | ELISA Kit for Hemojuvelin (HJV) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB995Ra | Multiplex Assay Kit for Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSB995Ra01 | ELISA Kit DIY Materials for Hemojuvelin (HJV) | Main materials for "Do It (ELISA Kit) Yourself". |