ELISA Kit for S100 Calcium Binding Protein A6 (S100A6)
S100-A6; 2A9; 5B10; CABP; CACY; PRA; MLN 4; Calcyclin; Growth factor-inducible protein 2A9; Prolactin receptor-associated protein
- Product No.SEB769Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range78-5,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 30pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 392
For more details, please contact local distributors! US$ 560 US$ 2520 US$ 4760 US$ 39200
Specificity
This assay has high sensitivity and excellent specificity for detection of S100 Calcium Binding Protein A6 (S100A6).
No significant cross-reactivity or interference between S100 Calcium Binding Protein A6 (S100A6) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant S100 Calcium Binding Protein A6 (S100A6) and the recovery rates were calculated by comparing the measured value to the expected amount of S100 Calcium Binding Protein A6 (S100A6) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 94-104 | 98 |
EDTA plasma(n=5) | 78-91 | 81 |
heparin plasma(n=5) | 95-103 | 101 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level S100 Calcium Binding Protein A6 (S100A6) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level S100 Calcium Binding Protein A6 (S100A6) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of S100 Calcium Binding Protein A6 (S100A6) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 79-97% | 97-105% | 95-103% | 84-101% |
EDTA plasma(n=5) | 83-97% | 93-102% | 92-99% | 93-103% |
heparin plasma(n=5) | 97-105% | 79-91% | 94-105% | 79-98% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
- Single-component Reagents of Assay Kit
- Lysis Buffer Specific for ELISA / CLIA
- Quality Control of Kit
- ELISA Kit Customized Service
- Disease Model Customized Service
- Serums Customized Service
- TGFB1 Activation Reagent
- Real Time PCR Experimental Service
- Streptavidin
- Fast blue Protein Stain solution
- Single-component Reagents of FLIA Kit
- Streptavidin-Agarose Beads
Magazine | Citations |
Journal of Proteomics | Tear proteome and protein network analyses reveal a novel pentamarker panel for tear film characterization in dry eye and meibomian gland dysfunction PubMed: 23201116 |
Tumour Biol | Diagnostic significance of S100A2 and S100A6 levels in sera of patients with non-small cell lung cancer PubMed: 26361956 |
Clinical and Translational Medicine | Serum levels of S100A6 are unaltered in patients with resectable cholangiocarcinoma pubmed:27709523 |
Gastroenterology | Tu1938-Micronutrients Assessment in Patients with Cirrhosis 10.1016:S0016-5085(18)33544-3 |
Gastroenterology | Tu1942-PI3K/AKT-Mediated Upregulation of C7 Inhibits Colorectal Cancer Proliferation and Metastasis 10.1016:S0016-5085(18)33544-5 |
Tumor Biology | Proteomics detection of S100A6 in tumor tissue interstitial fluid and evaluation of its potential as a biomarker of cholangiocarcinoma Pubmed:29629840 |
scandinavian journal of clinical & laboratory investigation | Serum S100A6, S100A8, S100A9 and S100A11 proteins in colorectal neoplasia: results of a single centre prospective study Pubmed: 31856598 |
CELL BIOCHEMISTRY AND FUNCTION | S100A6 represses Calu©\6 lung cancer cells growth via inhibiting cell proliferation, migration, invasion and enhancing apoptosis 34008212 |
MOLECULAR VISION | Quantification of a panel for dry-eye protein biomarkers in tears: A comparative pilot study using standard ELISA and customized microarrays 34012227 |