ELISA Kit for Apoptosis Inducing Factor (AIF)

PDCD8; Programmed Cell Death protein 8; Apoptosis-inducing factor 1, mitochondrial

Specificity

This assay has high sensitivity and excellent specificity for detection of Apoptosis Inducing Factor (AIF).
No significant cross-reactivity or interference between Apoptosis Inducing Factor (AIF) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Apoptosis Inducing Factor (AIF) and the recovery rates were calculated by comparing the measured value to the expected amount of Apoptosis Inducing Factor (AIF) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-104 83
EDTA plasma(n=5) 90-98 93
heparin plasma(n=5) 85-104 89

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Apoptosis Inducing Factor (AIF) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Apoptosis Inducing Factor (AIF) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Apoptosis Inducing Factor (AIF) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 82-89% 87-102% 93-101% 99-105%
EDTA plasma(n=5) 89-102% 90-97% 80-94% 79-104%
heparin plasma(n=5) 88-95% 87-103% 93-105% 95-102%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
РОЛЬ АПОПТОЗ ИНДУЦИРУЮЩЕГО ФАКТОРА И ОКИСЛИТЕЛЬНОГО СТРЕССА ПРИ ХРОНИЧЕСКОЙ СЕРДЕЧНОЙ НЕДОСТАТОЧНОСТИ 616-005.8
NEUROCHEMISTRY INTERNATIONAL Redox-active DJ-1 sustains brainstem cardiovascular regulation via maintenance of mitochondrial function during mevinphos intoxication Pubmed: 32650030
Iranian Journal of Basic Medical Sciences Chromon-3-aldehyde derivatives restore mitochondrial function in rat cerebral ischemia Pubmed: 32963739
Journal of?Pharmaceutical Sciences Correction of mitochondrial dysfunction by 4-hydroxy-3, 5-ditretbutyl cinnamic acid in experimental Alzheimer's disease induced by A¦Â injection in rats.
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB064Hu01 Recombinant Apoptosis Inducing Factor (AIF) Positive Control; Immunogen; SDS-PAGE; WB.
PAB064Hu01 Polyclonal Antibody to Apoptosis Inducing Factor (AIF) WB,IHC,ICC/IF
MAB064Hu22 Monoclonal Antibody to Apoptosis Inducing Factor (AIF) WB; IHC; ICC; IP.