ELISA Kit for Cytochrome P450 7A1 (CYP7A1)

CYP7; CYP7-A1; CYPVII; Cholesterol 7 Alpha Hydroxylase; Cytochrome P450 Family 7 Subfamily A Polypeptide 1

Specificity

This assay has high sensitivity and excellent specificity for detection of Cytochrome P450 7A1 (CYP7A1).
No significant cross-reactivity or interference between Cytochrome P450 7A1 (CYP7A1) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Cytochrome P450 7A1 (CYP7A1) and the recovery rates were calculated by comparing the measured value to the expected amount of Cytochrome P450 7A1 (CYP7A1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 85-104 99
EDTA plasma(n=5) 80-101 90
heparin plasma(n=5) 86-99 91

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cytochrome P450 7A1 (CYP7A1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cytochrome P450 7A1 (CYP7A1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cytochrome P450 7A1 (CYP7A1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-101% 84-93% 88-99% 86-101%
EDTA plasma(n=5) 90-97% 92-99% 85-98% 86-101%
heparin plasma(n=5) 80-98% 80-105% 98-105% 88-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Cell Reports Parabacteroides distasonis Alleviates Obesity and Metabolic Dysfunctions via Production of Succinate and Secondary Bile Acids Pubmed: 30605678
Journal of Functional Foods Hyperglycemia exacerbates dyslipidemia-induced changes in uptake, synthesis, and transporters of bile acids in rats: Assessment of restorative potentials of ALA and?… Doi: 10.1016/j.jff.2019.01.038
Journal of Agriculture and Food Research Withaferin-A down-regulate enterohepatic circulation of bile acids: An insight from a hyperlipidemic rat model
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPB053Mu02 Recombinant Cytochrome P450 7A1 (CYP7A1) Positive Control; Immunogen; SDS-PAGE; WB.
RPB053Mu01 Recombinant Cytochrome P450 7A1 (CYP7A1) Positive Control; Immunogen; SDS-PAGE; WB.
PAB053Mu02 Polyclonal Antibody to Cytochrome P450 7A1 (CYP7A1) WB; IHC; ICC; IP.
PAB053Mu01 Polyclonal Antibody to Cytochrome P450 7A1 (CYP7A1) WB; IHC; ICC; IP.
SEB053Mu ELISA Kit for Cytochrome P450 7A1 (CYP7A1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB053Mu Multiplex Assay Kit for Cytochrome P450 7A1 (CYP7A1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.