ELISA Kit for Angiotensin II Receptor 2 (AGTR2)

AT2R; AT2-R; ATGR2; AT2; MRX88

Specificity

This assay has high sensitivity and excellent specificity for detection of Angiotensin II Receptor 2 (AGTR2).
No significant cross-reactivity or interference between Angiotensin II Receptor 2 (AGTR2) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiotensin II Receptor 2 (AGTR2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiotensin II Receptor 2 (AGTR2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Journal of Atherosclerosis and Thrombosis Involvement of Angiotensin II Type 1 and 2 Receptors in Gelatinase ReCavia (Guinea pig )lation in Human Carotid Atheroma in vitro Pubmed:26947595
Molecular Medicine Reports Effects of IQP, VEP and Spirulina platensis hydrolysates on the local kidney renin angiotensin system in spontaneously hypertensive rats pubmed:28944898
Oxidative Medicine and Cellular Longevity Sinapic Acid Attenuates Cardiovascular Disorders in Rats by Modulating Reactive Oxygen Species and Angiotensin Receptor Expression Pubmed: 32765804
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPA973Ra01 Recombinant Angiotensin II Receptor 2 (AGTR2) Positive Control; Immunogen; SDS-PAGE; WB.
PAA973Ra01 Polyclonal Antibody to Angiotensin II Receptor 2 (AGTR2) WB; IHC; ICC; IP.
MAA973Ra21 Monoclonal Antibody to Angiotensin II Receptor 2 (AGTR2) WB; IHC; ICC; IP.
SEA973Ra ELISA Kit for Angiotensin II Receptor 2 (AGTR2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA973Ra Multiplex Assay Kit for Angiotensin II Receptor 2 (AGTR2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.