ELISA Kit for Inducible T-Cell Co Stimulator (ICOS)

CD278; AILIM; Inducible T-Cell Costimulator; Activation-Inducible Lymphocyte Immunomediatory Molecule

Specificity

This assay has high sensitivity and excellent specificity for detection of Inducible T-Cell Co Stimulator (ICOS).
No significant cross-reactivity or interference between Inducible T-Cell Co Stimulator (ICOS) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Inducible T-Cell Co Stimulator (ICOS) and the recovery rates were calculated by comparing the measured value to the expected amount of Inducible T-Cell Co Stimulator (ICOS) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-98 94
EDTA plasma(n=5) 90-97 94
heparin plasma(n=5) 80-103 81

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Inducible T-Cell Co Stimulator (ICOS) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Inducible T-Cell Co Stimulator (ICOS) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Inducible T-Cell Co Stimulator (ICOS) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-92% 79-89% 84-101% 79-98%
EDTA plasma(n=5) 98-105% 85-92% 79-97% 78-93%
heparin plasma(n=5) 89-101% 78-94% 94-101% 82-89%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Archives of Dermatological Research Increased production of soluble inducible costimulator in patients with diffuse cutaneous systemic sclerosis Pubmed: 23053221
DNA Cell Biol. Effect of soluble inducible costimulator level and its polymorphisms on age-related macular degeneration. Pubmed: 24083358
Rheumatology Augmented ICOS expression in patients with early diffuse cutaneous systemic sclerosis Pubmed: 23024058
Br J Haematol Inducible T‐cell co‐stimulator (ICOS) and ICOS ligand are novel players in the multiple‐myeloma microenvironment Pubmed:34954822
Diagnostics (Basel) Increased Levels of ICOS and ICOSL Are Associated to Pulmonary Arterial Hypertension in Patients Affected by Connective Tissue Diseases Pubmed:35328257
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA777Hu01 Recombinant Inducible T-Cell Co Stimulator (ICOS) Positive Control; Immunogen; SDS-PAGE; WB.
PAA777Hu01 Polyclonal Antibody to Inducible T-Cell Co Stimulator (ICOS) WB; IHC; ICC; IP.
FAA777Hu01 Anti-Inducible T-Cell Co Stimulator (ICOS) Polyclonal Antibody Flow cytometry.
LAA777Hu81 FITC-Linked Polyclonal Antibody to Inducible T-Cell Co Stimulator (ICOS) WB; IHC; ICC; IF.
LAA777Hu71 Biotin-Linked Polyclonal Antibody to Inducible T-Cell Co Stimulator (ICOS) WB; IHC; ICC.
FAA777Hu41 PE-Linked Anti-Inducible T-Cell Co Stimulator (ICOS) Polyclonal Antibody Flow cytometry.
FAA777Hu51 APC-Linked Anti-Inducible T-Cell Co Stimulator (ICOS) Polyclonal Antibody Flow cytometry.
FAA777Hu81 FITC-Linked Anti-Inducible T-Cell Co Stimulator (ICOS) Polyclonal Antibody Flow cytometry.
MAA777Hu22 Monoclonal Antibody to Inducible T-Cell Co Stimulator (ICOS) WB; IHC; ICC; IP.
RAA777Hu21 Recombinant Antibody to Inducible T-Cell Co Stimulator (ICOS) WB; IFC; IHC; IP.
SEA777Hu ELISA Kit for Inducible T-Cell Co Stimulator (ICOS) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA777Hu Multiplex Assay Kit for Inducible T-Cell Co Stimulator (ICOS) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.