ELISA Kit for Troponin I (TNI)

Tn-I; TNNI

Specificity

This assay has high sensitivity and excellent specificity for detection of Troponin I (TNI).
No significant cross-reactivity or interference between Troponin I (TNI) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Troponin I (TNI) and the recovery rates were calculated by comparing the measured value to the expected amount of Troponin I (TNI) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 81-91 85
EDTA plasma(n=5) 86-93 89
heparin plasma(n=5) 97-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Troponin I (TNI) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Troponin I (TNI) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Troponin I (TNI) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-103% 92-105% 98-105% 98-105%
EDTA plasma(n=5) 94-103% 81-99% 91-101% 86-98%
heparin plasma(n=5) 91-99% 89-97% 80-95% 78-93%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Asian Pac J Trop Med.  Effect of levocarnitine on TIMP-1, ICAM-1 expression of rats with coronary heart disease and its myocardial protection effect Pubmed:26972400
international journal of molecular sciences Adjustment of Dysregulated Ceramide Metabolism in a Murine Model of Sepsis-Induced Cardiac Dysfunction pubmed:28420138
Cellular Physiology and Biochemistry  Repeated Non-Invasive Limb Ischemic Preconditioning Confers Cardioprotection Through PKC-Ԑ/STAT3 Signaling in Diabetic Rats Pubmed:29533954
Oxidative Medicine and Cellular Longevity Sinapic Acid Attenuates Cardiovascular Disorders in Rats by Modulating Reactive Oxygen Species and Angiotensin Receptor Expression Pubmed: 32765804
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
SEA564Ra ELISA Kit for Troponin I (TNI) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA564Ra Multiplex Assay Kit for Troponin I (TNI) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.