ELISA Kit for Plasminogen Activator Inhibitor 2 (PAI2)

SERPINB2; PLANH2; Serpin Peptidase Inhibitor Clade B Member 2; Monocyte Arg-serpin; Placental plasminogen activator inhibitor; Serpin B2; Urokinase inhibitor

Specificity

This assay has high sensitivity and excellent specificity for detection of Plasminogen Activator Inhibitor 2 (PAI2).
No significant cross-reactivity or interference between Plasminogen Activator Inhibitor 2 (PAI2) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Plasminogen Activator Inhibitor 2 (PAI2) and the recovery rates were calculated by comparing the measured value to the expected amount of Plasminogen Activator Inhibitor 2 (PAI2) in samples.

Matrix Recovery range (%) Average(%)
sodium citrate plasma(n=5) 98-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Plasminogen Activator Inhibitor 2 (PAI2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Plasminogen Activator Inhibitor 2 (PAI2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Plasminogen Activator Inhibitor 2 (PAI2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
sodium citrate plasma(n=5) 79-101% 95-103% 97-104% 90-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
BBA Clinical Cerebrospinal fluid inflammatory markers in patients with?Listeria monocytogenes?meningitis Sciencedirect:S2214647414000087
JCI Insight The senescence-associated secretome as an indicator of age and medical risk Pubmed: 32554926
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APA531Hu61 Active Plasminogen Activator Inhibitor 2 (PAI2) Cell culture; Activity Assays.
EPA531Hu61 Eukaryotic Plasminogen Activator Inhibitor 2 (PAI2) Positive Control; Immunogen; SDS-PAGE; WB.
APA531Hu01 Active Plasminogen Activator Inhibitor 2 (PAI2) Cell culture; Activity Assays.
RPA531Hu01 Recombinant Plasminogen Activator Inhibitor 2 (PAI2) Positive Control; Immunogen; SDS-PAGE; WB.
PAA531Hu01 Polyclonal Antibody to Plasminogen Activator Inhibitor 2 (PAI2) WB; IHC; ICC; IP.
MAA531Hu22 Monoclonal Antibody to Plasminogen Activator Inhibitor 2 (PAI2) WB; IHC; ICC; IP.
SEA531Hu ELISA Kit for Plasminogen Activator Inhibitor 2 (PAI2) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA531Hu CLIA Kit for Plasminogen Activator Inhibitor 2 (PAI2) Chemiluminescent immunoassay for Antigen Detection.
LMA531Hu Multiplex Assay Kit for Plasminogen Activator Inhibitor 2 (PAI2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.