Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Mini Samples ELISA Kit for Tumor Necrosis Factor Beta (TNFb)
LT; LTA; TNF-B; TNFSF1; Tumor Necrosis Factor Ligand Superfamily Member 1; Lymphotoxin Alpha
- Product No.MEA134Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range7.8-500pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 3.2pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 545
For more details, please contact local distributors! US$ 778 US$ 3501 US$ 6613 US$ 54460
Specificity
This assay has high sensitivity and excellent specificity for detection of Mini Samples Tumor Necrosis Factor Beta (TNFb).
No significant cross-reactivity or interference between Mini Samples Tumor Necrosis Factor Beta (TNFb) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Mini Samples Tumor Necrosis Factor Beta (TNFb) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Tumor Necrosis Factor Beta (TNFb) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 78-101 | 84 |
EDTA plasma(n=5) | 85-93 | 89 |
heparin plasma(n=5) | 79-91 | 78 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Tumor Necrosis Factor Beta (TNFb) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Tumor Necrosis Factor Beta (TNFb) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Tumor Necrosis Factor Beta (TNFb) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 88-101% | 78-94% | 94-105% | 78-96% |
EDTA plasma(n=5) | 85-95% | 84-101% | 92-101% | 78-101% |
heparin plasma(n=5) | 95-102% | 90-97% | 94-105% | 84-94% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×60µL | Assay Diluent A | 1×6mL |
Detection Reagent B | 1×60µL | Assay Diluent B | 1×6mL |
TMB Substrate | 1×4.5mL | Stop Solution | 1×3mL |
Wash Buffer (30 × concentrate) | 1×10mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Journal of Applied Physiology | Simvastatin attenuates sympathetic hyperinnervation to prevent atrial fibrillation during the postmyocardial infarction remodeling process PubMed: 22984252 |
Journal of Translational Medicine | Effectiveness of pure argon for renal transplant preservation in a preclinical pig model of heterotopic autotransplantation Pubmed:26847569 |
International Journal of Stem Cell Research and Transplantation | Protective Role of Bone Marrow Derived Mesenchymal Stem Cells-Conditioned Medium in the Infarcted Myocardium: The Potential Role of Selected Cytokines IJST-2328-3548-04-803 |
Probiotics Antimicrob Proteins | Effect of Multi-Microbial Probiotic Formulation Bokashi on Pro-and Anti-Inflammatory Cytokines Profile in the Serum, Colostrum and Milk of Sows, and in a … Pubmed:29305686 |
Parasites & Vectors | Fasciola gigantica excretory-secretory products (FgESPs) modulate the differentiation and immune functions of buffalo dendritic cells through a mechanism … Pubmed: 32680553 |
Microbiome changes in patients with chronic heart failure with preserved ejection fraction correlate with fibrosis markers: Description of a Russian cohort | |
BMC MUSCULOSKELETAL DISORDERS | Elevated lymphotoxin-¦Á (TNF¦Â) is associated with intervertebral disc degeneration 33441130 |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
RPA134Mu02 | Recombinant Tumor Necrosis Factor Beta (TNFb) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA134Mu01 | Recombinant Tumor Necrosis Factor Beta (TNFb) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA134Mu01 | Polyclonal Antibody to Tumor Necrosis Factor Beta (TNFb) | WB; IHC; ICC; IP. |
PAA134Mu02 | Polyclonal Antibody to Tumor Necrosis Factor Beta (TNFb) | WB; IHC; ICC; IP. |
LAA134Mu71 | Biotin-Linked Polyclonal Antibody to Tumor Necrosis Factor Beta (TNFb) | WB; IHC; ICC. |
MEA134Mu | Mini Samples ELISA Kit for Tumor Necrosis Factor Beta (TNFb) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SEA134Mu | ELISA Kit for Tumor Necrosis Factor Beta (TNFb) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA134Mu | Multiplex Assay Kit for Tumor Necrosis Factor Beta (TNFb) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |