Multiplex Assay Kit for Sirtuin 6 (SIRT6) ,etc. by FLIA (Flow Luminescence Immunoassay)

SIR2L6; Silent Mating Type Information Regulation 2 Homolog 6; Mono-ADP-Ribosyltransferase Sirtuin-6; Regulatory protein SIR2 homolog 6; SIR2-like protein 6

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Sirtuin 6 (SIRT6) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Sirtuin 6 (SIRT6) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Sirtuin 6 (SIRT6) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Sirtuin 6 (SIRT6) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 85-101 93
EDTA plasma(n=5) 95-105 98
heparin plasma(n=5) 78-93 83
sodium citrate plasma(n=5) 89-99 94

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Sirtuin 6 (SIRT6) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Sirtuin 6 (SIRT6) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Sirtuin 6 (SIRT6) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-101% 78-90% 85-99% 82-96%
EDTA plasma(n=5) 80-92% 79-89% 82-91% 83-90%
heparin plasma(n=5) 95-105% 83-90% 93-105% 90-99%
sodium citrate plasma(n=5) 94-103% 82-97% 78-95% 88-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:SIRT6) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
International Journal of Pharmacy and Pharmaceutical Sciences SIRT6 is correlated with estradiol in women with in vitro fertilization failure profile:Hussein_Alhakeim
Journal of International Medical Research Serum and follicular fluid levels of sirtuin 1, sirtuin 6, and resveratrol in women undergoing fertilization: an observational, clinical study Pubmed: 30556451
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPE916Hu01 Recombinant Sirtuin 6 (SIRT6) Positive Control; Immunogen; SDS-PAGE; WB.
RPE916Hu02 Recombinant Sirtuin 6 (SIRT6) Positive Control; Immunogen; SDS-PAGE; WB.
PAE916Hu01 Polyclonal Antibody to Sirtuin 6 (SIRT6) WB; IHC; ICC; IP.
LAE916Hu81 FITC-Linked Polyclonal Antibody to Sirtuin 6 (SIRT6) WB; IHC; ICC; IF.
LAE916Hu71 Biotin-Linked Polyclonal Antibody to Sirtuin 6 (SIRT6) WB; IHC; ICC.
MAE916Hu21 Monoclonal Antibody to Sirtuin 6 (SIRT6) WB; IHC; ICC; IP.
SEE916Hu ELISA Kit for Sirtuin 6 (SIRT6) Enzyme-linked immunosorbent assay for Antigen Detection.
LME916Hu Multiplex Assay Kit for Sirtuin 6 (SIRT6) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.