Multiplex Assay Kit for Farnesoid X Receptor (FXR) ,etc. by FLIA (Flow Luminescence Immunoassay)
NR1H4; BAR; FXR; HRR1; RIP14; Nuclear Receptor Subfamily 1,Group H,Member 4; Bile acid receptor; Farnesol receptor HRR-1; Retinoid X receptor-interacting protein 14
(Note: Up to 8-plex in one testing reaction)
- Product No.LMC042Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample TypeTissue homogenates, cell lysates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.01-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.003 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 449
US$ 467
US$ 492
US$ 527
US$ 562
US$ 613
US$ 691
Result
For more details, please contact local distributors! US$ 864 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Farnesoid X Receptor (FXR) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Farnesoid X Receptor (FXR) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Farnesoid X Receptor (FXR) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Farnesoid X Receptor (FXR) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 79-104 | 97 |
EDTA plasma(n=5) | 89-104 | 96 |
heparin plasma(n=5) | 82-93 | 86 |
sodium citrate plasma(n=5) | 96-104 | 101 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Farnesoid X Receptor (FXR) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Farnesoid X Receptor (FXR) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Farnesoid X Receptor (FXR) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 83-99% | 90-104% | 78-105% | 93-105% |
EDTA plasma(n=5) | 90-104% | 87-94% | 92-104% | 83-97% |
heparin plasma(n=5) | 89-99% | 93-101% | 95-104% | 84-99% |
sodium citrate plasma(n=5) | 89-98% | 92-101% | 78-103% | 78-90% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:FXR) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
The Journal of Nutritional Biochemistry | Raspberry pomace alters cecal microbial activity and reduces secondary bile acids in rats fed a high-fat diet. pubmed:28437712 |
Chinese Journal of Natural Medicines | Hypolipidemic effect of SIPI-7623, a derivative of an extract from oriental wormwood, through farnesoid X receptor antagonism Pubmed: 30197122 |
Cytotechnology | d-Allulose enhances uptake of HDL-cholesterol into rat's primary hepatocyte via SR-B1 Pubmed: 32086695 |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
RPC042Mu01 | Recombinant Farnesoid X Receptor (FXR) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPC042Mu02 | Recombinant Farnesoid X Receptor (FXR) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAC042Mu02 | Polyclonal Antibody to Farnesoid X Receptor (FXR) | WB; IHC; ICC; IP. |
PAC042Mu01 | Polyclonal Antibody to Farnesoid X Receptor (FXR) | WB; IHC; ICC; IP. |
SEC042Mu | ELISA Kit for Farnesoid X Receptor (FXR) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMC042Mu | Multiplex Assay Kit for Farnesoid X Receptor (FXR) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |