Multiplex Assay Kit for Complement Factor I (CFI) ,etc. by FLIA (Flow Luminescence Immunoassay)

CF-I; C3b-INA; FI; IF; KAF; Factor I; Konglutinogen-Activating Factor; C3b-Inactivator; C3B/C4B inactivator

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Complement Factor I (CFI) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Complement Factor I (CFI) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Complement Factor I (CFI) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Complement Factor I (CFI) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 87-101 92
EDTA plasma(n=5) 97-104 101
heparin plasma(n=5) 80-101 91
sodium citrate plasma(n=5) 88-101 94

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement Factor I (CFI) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement Factor I (CFI) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Complement Factor I (CFI) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-95% 94-101% 82-97% 80-96%
EDTA plasma(n=5) 91-103% 98-105% 80-89% 84-93%
heparin plasma(n=5) 96-104% 79-96% 90-104% 88-102%
sodium citrate plasma(n=5) 91-105% 99-105% 85-101% 79-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CFI) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
J Thromb Haemost A case report of thrombotic microangiopathy without renal involvement carrying two novel mutations in complement-regulator genes PubMed: 26613809
Pediatr Int Atypical hemolytic uremic syndrome: Korean pediatric series PubMed: 25443527
United States Patent Application  NOVEL ASSAY y2016:139118
Researchgate Compliment factor i bioassay US20170285024
PLoS One A monoclonal antibody targeting amyloid β (Aβ) restores complement factor I bioactivity: Potential implications in age-related macular degeneration and … Pubmed:29782502
JOURNAL OF CELLULAR AND MOLECULAR MEDICINE The importance of sialic acid, pH and ion concentration on the interaction of uromodulin and complement factor H 33788378
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB978Hu02 Recombinant Complement Factor I (CFI) Positive Control; Immunogen; SDS-PAGE; WB.
RPB978Hu01 Recombinant Complement Factor I (CFI) Positive Control; Immunogen; SDS-PAGE; WB.
PAB978Hu01 Polyclonal Antibody to Complement Factor I (CFI) WB; IHC; ICC; IP.
PAB978Hu02 Polyclonal Antibody to Complement Factor I (CFI) WB; IHC; ICC; IP.
MAB978Hu22 Monoclonal Antibody to Complement Factor I (CFI) WB; IHC; ICC; IP.
WEB978Hu Wide-range ELISA Kit for Complement Factor I (CFI) Enzyme-linked immunosorbent assay for Antigen Detection.
SEB978Hu ELISA Kit for Complement Factor I (CFI) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB978Hu Multiplex Assay Kit for Complement Factor I (CFI) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.