Multiplex Assay Kit for Histone Acetyltransferase 1 (HAT1) ,etc. by FLIA (Flow Luminescence Immunoassay)

KAT1; Histone acetyltransferase type B catalytic subunit

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Histone Acetyltransferase 1 (HAT1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Histone Acetyltransferase 1 (HAT1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Histone Acetyltransferase 1 (HAT1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Histone Acetyltransferase 1 (HAT1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:HAT1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPB952Ra01 Recombinant Histone Acetyltransferase 1 (HAT1) Positive Control; Immunogen; SDS-PAGE; WB.
PAB952Ra01 Polyclonal Antibody to Histone Acetyltransferase 1 (HAT1) WB; IHC; ICC; IP.
MAB952Ra21 Monoclonal Antibody to Histone Acetyltransferase 1 (HAT1) WB; IHC; ICC; IP.
SEB952Ra ELISA Kit for Histone Acetyltransferase 1 (HAT1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB952Ra Multiplex Assay Kit for Histone Acetyltransferase 1 (HAT1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.