Multiplex Assay Kit for Histone Acetyltransferase 1 (HAT1) ,etc. by FLIA (Flow Luminescence Immunoassay)

KAT1; Histone acetyltransferase type B catalytic subunit

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Histone Acetyltransferase 1 (HAT1).
No significant cross-reactivity or interference between Histone Acetyltransferase 1 (HAT1) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Histone Acetyltransferase 1 (HAT1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Histone Acetyltransferase 1 (HAT1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:HAT1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPB952Ra01 Recombinant Histone Acetyltransferase 1 (HAT1) Positive Control; Immunogen; SDS-PAGE; WB.
PAB952Ra01 Polyclonal Antibody to Histone Acetyltransferase 1 (HAT1) WB; IHC; ICC; IP.
MAB952Ra21 Monoclonal Antibody to Histone Acetyltransferase 1 (HAT1) WB; IHC; ICC; IP.
SEB952Ra ELISA Kit for Histone Acetyltransferase 1 (HAT1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB952Ra Multiplex Assay Kit for Histone Acetyltransferase 1 (HAT1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMB952Ra Multiplex Assay Kit for Histone Acetyltransferase 1 (HAT1) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.