Multiplex Assay Kit for Immunoglobulin G2 (IgG2) ,etc. by FLIA (Flow Luminescence Immunoassay)

IGHG2; Ig Gamma-2 Chain C Region; Immunoglobulin Heavy Constant Gamma 2; G2m Marker; Immunoglobulin Gm2

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Immunoglobulin G2 (IgG2) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Immunoglobulin G2 (IgG2) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Immunoglobulin G2 (IgG2) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Immunoglobulin G2 (IgG2) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-101 86
EDTA plasma(n=5) 96-105 101
heparin plasma(n=5) 79-104 84
sodium citrate plasma(n=5) 78-97 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Immunoglobulin G2 (IgG2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Immunoglobulin G2 (IgG2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Immunoglobulin G2 (IgG2) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 78-98% 80-101% 79-102% 93-101%
EDTA plasma(n=5) 85-92% 95-102% 95-102% 81-104%
heparin plasma(n=5) 82-94% 91-101% 78-94% 82-98%
sodium citrate plasma(n=5) 89-99% 91-99% 82-101% 94-101%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:IgG2) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
BioMed Research International The Effect of CXC Motif Chemokine 13 on Hepatocellular Carcinoma Associates with Wnt Signaling Hindawi:Source
Oncology Reports Beneficial effect of T follicular helper cells on antibody class switching of B cells in prostate cancer Pubmed:25529861
Biomed Res Int The Effect of C-X-C Motif Chemokine 13 on Hepatocellular Carcinoma Associates with Wnt Signaling PubMed: 26161394
Catalog No. Related products for research use of Cavia (Guinea pig ) Organism species Applications (RESEARCH USE ONLY!)
NPB682Gu01 Native Immunoglobulin G2 (IgG2) Positive Control; Immunogen; SDS-PAGE; WB.
RPB682Gu01 Recombinant Immunoglobulin G2 (IgG2) Positive Control; Immunogen; SDS-PAGE; WB.
PAB682Gu01 Polyclonal Antibody to Immunoglobulin G2 (IgG2) WB; IHC; ICC; IP.
MAB682Gu21 Monoclonal Antibody to Immunoglobulin G2 (IgG2) WB; IHC; ICC; IP.
CEB682Gu ELISA Kit for Immunoglobulin G2 (IgG2) Enzyme-linked immunosorbent assay for Antigen Detection.