Multiplex Assay Kit for Sorbitol Dehydrogenase (SDH) ,etc. by FLIA (Flow Luminescence Immunoassay)
SORD; L-iditol 2-dehydrogenase
(Note: Up to 8-plex in one testing reaction)
- Product No.LMB495Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.02-20ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.007 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 415
US$ 431
US$ 455
US$ 487
US$ 519
US$ 567
US$ 638
Result
For more details, please contact local distributors! US$ 798 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Sorbitol Dehydrogenase (SDH) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Sorbitol Dehydrogenase (SDH) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Sorbitol Dehydrogenase (SDH) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Sorbitol Dehydrogenase (SDH) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 80-101 | 86 |
EDTA plasma(n=5) | 87-103 | 96 |
heparin plasma(n=5) | 81-99 | 91 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Sorbitol Dehydrogenase (SDH) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Sorbitol Dehydrogenase (SDH) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Sorbitol Dehydrogenase (SDH) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 95-105% | 89-98% | 90-98% | 90-105% |
EDTA plasma(n=5) | 78-95% | 80-95% | 80-96% | 82-103% |
heparin plasma(n=5) | 91-101% | 78-90% | 80-103% | 83-91% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:SDH) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Kafkas Univ Vet Fak Derg | The Importance of Concentrations of Sorbitol Dehydrogenase and Glutamate Dehydrogenase and B-Mode Ultrasonographic Examination in The Diagnosis of Hepatic Lipidosis in Dairy Cows Kafkas: Source |
Journal of Food Science and Technology | Grape seed extract and Zinc containing nutritional food supplement delays onset and progression of Streptozocin-induced diabetic cataract in Wistar rats Springer: Source |
Clinical and Experimental Optometry | Aldo-keto reductase and sorbitol dehydrogenase enzymes in Egyptian diabetic patients with and without proliferative diabetic retinopathy. Pubmed: 23452182 |
Biomedicine & Pharmacotherapy | Zinc/alogliptin combination attenuates testicular toxicity induced by doxorubicin in rats: Role of oxidative stress, apoptosis and TGF-β1/NF-κB signaling pubmed:29091894 |
Molecular Medicine Reports | Protective effects of N (2)‑L‑alanyl‑L‑glutamine mediated by the JAK2/STAT3 signaling pathway on myocardial ischemia reperfusion Pubmed:29393473 |
Effect of the combination between empagliflozin and calcipotriol on cadmium-induced testicular toxicity in rats |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
RPB495Hu01 | Recombinant Sorbitol Dehydrogenase (SDH) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB495Hu01 | Polyclonal Antibody to Sorbitol Dehydrogenase (SDH) | WB; IHC; ICC; IP. |
MAB495Hu22 | Monoclonal Antibody to Sorbitol Dehydrogenase (SDH) | WB; IHC; ICC; IP. |
SEB495Hu | ELISA Kit for Sorbitol Dehydrogenase (SDH) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB495Hu | Multiplex Assay Kit for Sorbitol Dehydrogenase (SDH) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |