Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Aryl Hydrocarbon Receptor (AhR) ,etc. by FLIA (Flow Luminescence Immunoassay)
BHLHE76; Class E basic helix-loop-helix protein 76
(Note: Up to 8-plex in one testing reaction)
- Product No.LMB354Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample Typetissue homogenates, cell lysates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range4.88-5000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 1.627 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 415
US$ 431
US$ 455
US$ 487
US$ 519
US$ 567
US$ 638
Result
For more details, please contact local distributors! US$ 798 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Aryl Hydrocarbon Receptor (AhR) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Aryl Hydrocarbon Receptor (AhR) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Aryl Hydrocarbon Receptor (AhR) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Aryl Hydrocarbon Receptor (AhR) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 92-105 | 95 |
EDTA plasma(n=5) | 87-96 | 92 |
heparin plasma(n=5) | 90-105 | 98 |
sodium citrate plasma(n=5) | 98-105 | 102 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Aryl Hydrocarbon Receptor (AhR) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Aryl Hydrocarbon Receptor (AhR) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Aryl Hydrocarbon Receptor (AhR) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 97-105% | 88-95% | 78-90% | 80-101% |
EDTA plasma(n=5) | 96-104% | 79-102% | 99-105% | 86-105% |
heparin plasma(n=5) | 87-103% | 97-105% | 80-98% | 83-93% |
sodium citrate plasma(n=5) | 79-101% | 88-96% | 83-98% | 86-102% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:AhR) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Molecular and Cellular Endocrinology | Isomer-nonspecific action of dichlorodiphenyltrichloroethane on aryl hydrocarbon receptor and G-protein-coupled receptor 30 intracellular signaling in apoptotic neuronal cells Pubmed:24859647 |
Journal of Steroid Biochemistry and Molecular Biology | Depressive-like effect of prenatal exposure to DDT involves global DNA hypomethylation and impairment of GPER1/ESR1 protein levels but not ESR2 and AHR/ARNT signaling pubmed:28263910 |
Biol Trace Elem Res | Investigation of Aryl Hydrocarbon Receptor, Zinc, and Vitamin B12 Levels in Chronic Gastritis with Helicobacter pylori Infection 33723799 |
Int J Clin Pract | Association of aryl hydrocarbon receptor (AhR) serum level and gene rs10247158 polymorphism with anthropometric, biochemical parameters and food consumption ¡ 34091989 |
Catalog No. | Related products for research use of Homo sapiens (Human) Organism species | Applications (RESEARCH USE ONLY!) |
APB354Hu01 | Active Aryl Hydrocarbon Receptor (AhR) | Cell culture; Activity Assays. |
RPB354Hu01 | Recombinant Aryl Hydrocarbon Receptor (AhR) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB354Hu01 | Polyclonal Antibody to Aryl Hydrocarbon Receptor (AhR) | WB; IHC; ICC/IF |
MAB354Hu22 | Monoclonal Antibody to Aryl Hydrocarbon Receptor (AhR) | WB; IHC; ICC; IP. |
MAB354Hu21 | Monoclonal Antibody to Aryl Hydrocarbon Receptor (AhR) | WB; IHC; ICC; IP. |
SEB354Hu | ELISA Kit for Aryl Hydrocarbon Receptor (AhR) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCB354Hu | CLIA Kit for Aryl Hydrocarbon Receptor (AhR) | Chemiluminescent immunoassay for Antigen Detection. |
LMB354Hu | Multiplex Assay Kit for Aryl Hydrocarbon Receptor (AhR) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |