Multiplex Assay Kit for Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by FLIA (Flow Luminescence Immunoassay)

ACTC; CMD1R; CMD1-R; ACT-a1

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-104 97
EDTA plasma(n=5) 78-96 88
heparin plasma(n=5) 90-104 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 84-101% 80-103% 79-96% 78-102%
EDTA plasma(n=5) 79-102% 85-98% 86-94% 83-101%
heparin plasma(n=5) 92-101% 92-101% 84-97% 81-92%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:ACTC1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Research Quarterly for Exercise and Sport Plasma α-Actin as an Early Marker of Muscle Damage After Repeated Bouts of Eccentric Cycling Pubmed:35522171
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB341Hu01 Recombinant Actin Alpha 1, Cardiac Muscle (ACTC1) Positive Control; Immunogen; SDS-PAGE; WB.
PAB341Hu01 Polyclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) WB; IHC; FCM
PAB341Hu51 Polyclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) WB; IHC; ICC; IP.
CAB341Hu01 Anti-Actin Alpha 1, Cardiac Muscle (ACTC1) Polyclonal Antibody WB; IHC
MAB341Hu27 Monoclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) IHC
MAB341Hu29 Monoclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) IHC
MAB341Hu26 Monoclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) ICC/IF
MAB341Hu22 Monoclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) WB; IHC
MAB341Hu23 Monoclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) WB; IHC
MAB341Hu24 Monoclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) WB; IHC
MAB341Hu25 Monoclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) WB; IHC
MAB341Hu21 Monoclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) WB; IHC
CAB341Hu22 Anti-Actin Alpha 1, Cardiac Muscle (ACTC1) Monoclonal Antibody WB; IHC
SEB341Hu ELISA Kit for Actin Alpha 1, Cardiac Muscle (ACTC1) Enzyme-linked immunosorbent assay for Antigen Detection.
AEB341Hu ELISA Kit for Anti-Actin Alpha 1, Cardiac Muscle Antibody (Anti-ACTC1) Enzyme-linked immunosorbent assay for Antibody Detection.
LMB341Hu Multiplex Assay Kit for Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.