Multiplex Assay Kit for Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by CBA (Cytometric Bead Array)

ACTC; CMD1R; CMD1-R; ACT-a1

Specificity

This assay has high sensitivity and excellent specificity for detection of Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 85-95 91
EDTA plasma(n=5) 94-101 98
heparin plasma(n=5) 81-101 94

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 83-97% 85-93% 80-93%
EDTA plasma(n=5) 85-99% 98-105% 91-101% 78-101%
heparin plasma(n=5) 92-101% 79-96% 78-93% 78-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Research Quarterly for Exercise and Sport Plasma α-Actin as an Early Marker of Muscle Damage After Repeated Bouts of Eccentric Cycling Pubmed:35522171
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB341Hu01 Recombinant Actin Alpha 1, Cardiac Muscle (ACTC1) Positive Control; Immunogen; SDS-PAGE; WB.
PAB341Hu01 Polyclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) WB; IHC; FCM
PAB341Hu51 Polyclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) WB; IHC; ICC; IP.
CAB341Hu01 Anti-Actin Alpha 1, Cardiac Muscle (ACTC1) Polyclonal Antibody WB; IHC
MAB341Hu27 Monoclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) IHC
MAB341Hu29 Monoclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) IHC
MAB341Hu26 Monoclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) ICC/IF
MAB341Hu22 Monoclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) WB; IHC
MAB341Hu23 Monoclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) WB; IHC
MAB341Hu24 Monoclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) WB; IHC
MAB341Hu25 Monoclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) WB; IHC
MAB341Hu21 Monoclonal Antibody to Actin Alpha 1, Cardiac Muscle (ACTC1) WB; IHC
CAB341Hu22 Anti-Actin Alpha 1, Cardiac Muscle (ACTC1) Monoclonal Antibody WB; IHC
SEB341Hu ELISA Kit for Actin Alpha 1, Cardiac Muscle (ACTC1) Enzyme-linked immunosorbent assay for Antigen Detection.
AEB341Hu ELISA Kit for Anti-Actin Alpha 1, Cardiac Muscle Antibody (Anti-ACTC1) Enzyme-linked immunosorbent assay for Antibody Detection.
CMB341Hu Multiplex Assay Kit for Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMB341Hu Multiplex Assay Kit for Actin Alpha 1, Cardiac Muscle (ACTC1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.