Multiplex Assay Kit for Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay)

GSTP1; GST-P1; DFN7; FAEES3; GST3

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 85-97 90
EDTA plasma(n=5) 98-105 101
heparin plasma(n=5) 96-103 101
sodium citrate plasma(n=5) 97-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 86-97% 87-104% 94-101%
EDTA plasma(n=5) 81-101% 80-92% 95-105% 98-105%
heparin plasma(n=5) 93-101% 79-95% 89-96% 88-102%
sodium citrate plasma(n=5) 80-91% 93-101% 97-105% 81-90%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:GSTp) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
International Journal of Medical Sciences Glutathione S-Transferase P1 Correlated with Oxidative Stress in Hepatocellular Carcinoma PubMed: PMC3619117
Mol Neurobiol Human Glutathione S-Transferase Enzyme Gene Polymorphisms and Their Association With Neurocysticercosis Pubmed:27021019
Journal of Biomaterials and Tissue Engineering 3D Printing of Differentiated Bone Marrow Mesenchymal Cells as a New Method for Liver Tissue Engineering art00007
Neuroscience Bulletin Comprehensive proteomic profiling of patients' tears identifies potential biomarkers for the traumatic vegetative state Pubmed:30019218
Arabian Journal of Chemistry Attenuating effect of Indole-3-Carbinol on gold nanoparticle induced hepatotoxicity in rats
International Journal of Nature and Life Sciences The Role of Glutathione S-Transferases in Pleomorphic Adenomas of the Salivary Glands
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPB090Ra01 Recombinant Glutathione S Transferase Pi (GSTp) Positive Control; Immunogen; SDS-PAGE; WB.
APB090Ra01 Active Glutathione S Transferase Pi (GSTp) Cell culture; Activity Assays.
PAB090Ra01 Polyclonal Antibody to Glutathione S Transferase Pi (GSTp) WB; IHC; ICC; IP.
LAB090Ra71 Biotin-Linked Polyclonal Antibody to Glutathione S Transferase Pi (GSTp) WB; IHC; ICC.
SEB090Ra ELISA Kit for Glutathione S Transferase Pi (GSTp) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB090Ra Multiplex Assay Kit for Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSB090Ra01 ELISA Kit DIY Materials for Glutathione S Transferase Pi (GSTp) Main materials for "Do It(ELISA Kit) Yourself"