Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay)
GSTP1; GST-P1; DFN7; FAEES3; GST3
(Note: Up to 8-plex in one testing reaction)
- Product No.LMB090Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.01-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.003 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 415
US$ 431
US$ 455
US$ 487
US$ 519
US$ 567
US$ 638
Result
For more details, please contact local distributors! US$ 798 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 89-103 | 94 |
EDTA plasma(n=5) | 80-90 | 86 |
heparin plasma(n=5) | 94-101 | 97 |
sodium citrate plasma(n=5) | 84-98 | 90 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glutathione S Transferase Pi (GSTp) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 85-92% | 78-94% | 80-94% | 82-89% |
EDTA plasma(n=5) | 88-101% | 98-105% | 89-97% | 87-103% |
heparin plasma(n=5) | 84-95% | 82-90% | 92-101% | 88-96% |
sodium citrate plasma(n=5) | 94-101% | 78-98% | 89-97% | 80-92% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:GSTp) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
International Journal of Medical Sciences | Glutathione S-Transferase P1 Correlated with Oxidative Stress in Hepatocellular Carcinoma PubMed: PMC3619117 |
Mol Neurobiol | Human Glutathione S-Transferase Enzyme Gene Polymorphisms and Their Association With Neurocysticercosis Pubmed:27021019 |
Journal of Biomaterials and Tissue Engineering | 3D Printing of Differentiated Bone Marrow Mesenchymal Cells as a New Method for Liver Tissue Engineering art00007 |
Neuroscience Bulletin | Comprehensive proteomic profiling of patients' tears identifies potential biomarkers for the traumatic vegetative state Pubmed:30019218 |
Arabian Journal of Chemistry | Attenuating effect of Indole-3-Carbinol on gold nanoparticle induced hepatotoxicity in rats |
International Journal of Nature and Life Sciences | The Role of Glutathione S-Transferases in Pleomorphic Adenomas of the Salivary Glands |