Multiplex Assay Kit for Alanine Aminopeptidase (AAP) ,etc. by FLIA (Flow Luminescence Immunoassay)

CD13; ALAP; P150; ANPEP; APN; LAP1; PEPN; Gp150; Aminopeptidase M; Microsomal Aminopeptidase; Alanyl Membrane Aminopeptidase; Aminopeptidase N

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Alanine Aminopeptidase (AAP) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Alanine Aminopeptidase (AAP) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Alanine Aminopeptidase (AAP) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Alanine Aminopeptidase (AAP) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 82-89 86
EDTA plasma(n=5) 82-95 90
heparin plasma(n=5) 93-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Alanine Aminopeptidase (AAP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Alanine Aminopeptidase (AAP) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Alanine Aminopeptidase (AAP) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-101% 80-101% 78-93% 80-101%
EDTA plasma(n=5) 85-101% 81-89% 82-101% 78-96%
heparin plasma(n=5) 92-103% 94-102% 79-88% 78-90%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:AAP) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Life Sciences Adipose tissue regulates hepatic cholesterol metabolism via adiponectin Pubmed:25445438
Sci Rep. Genomic reprograming analysis of the Mesothelial to Mesenchymal Transition identifies biomarkers in peritoneal dialysis patients. pubmed:28327551
Analytical Chemistry In Vivo Two-Photon Fluorescence Imaging of the Activity of the Inflammatory Biomarker LTAH in a Mouse Pneumonia Model Pubmed:29682967
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
EPB065Hu61 Eukaryotic Alanine Aminopeptidase (AAP) Positive Control; Immunogen; SDS-PAGE; WB.
APB065Hu61 Active Alanine Aminopeptidase (AAP) Cell culture; Activity Assays.
RPB065Hu01 Recombinant Alanine Aminopeptidase (AAP) Positive Control; Immunogen; SDS-PAGE; WB.
RPB065Hu02 Recombinant Alanine Aminopeptidase (AAP) Positive Control; Immunogen; SDS-PAGE; WB.
PAB065Hu01 Polyclonal Antibody to Alanine Aminopeptidase (AAP) WB; IHC; ICC; IP.
MAB065Hu21 Monoclonal Antibody to Alanine Aminopeptidase (AAP) WB; IHC; ICC; IP.
MAB065Hu22 Monoclonal Antibody to Alanine Aminopeptidase (AAP) WB; IHC; ICC; IP.
MAB065Hu26 Monoclonal Antibody to Alanine Aminopeptidase (AAP) WB; IHC; ICC; IP.
FAB065Hu02 Anti-Alanine Aminopeptidase (AAP) Monoclonal Antibody FCM
FAB065Hu04 Anti-Alanine Aminopeptidase (AAP) Monoclonal Antibody FCM
SEB065Hu ELISA Kit for Alanine Aminopeptidase (AAP) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB065Hu Multiplex Assay Kit for Alanine Aminopeptidase (AAP) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.