Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for 1,5-Anhydroglucitol (1,5-AG) ,etc. by FLIA (Flow Luminescence Immunoassay)
LycoMark; 1-Deoxy-D-glucose; 1-Deoxy-D-glucopyranose; 1,5-Anhydro-D-glucitol; 1,5-Anhydrosorbitol; Aceritol; Polygalytol
(Note: Up to 8-plex in one testing reaction)
- Product No.LMB046Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample Typeserum, plasma and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range0.15-150ug/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.05 ug/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 504
US$ 524
US$ 553
US$ 592
US$ 631
US$ 689
US$ 776
Result
For more details, please contact local distributors! US$ 970 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of 1,5-Anhydroglucitol (1,5-AG) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between 1,5-Anhydroglucitol (1,5-AG) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of 1,5-Anhydroglucitol (1,5-AG) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of 1,5-Anhydroglucitol (1,5-AG) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 80-102 | 96 |
EDTA plasma(n=5) | 78-95 | 84 |
heparin plasma(n=5) | 88-104 | 98 |
sodium citrate plasma(n=5) | 91-98 | 94 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level 1,5-Anhydroglucitol (1,5-AG) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level 1,5-Anhydroglucitol (1,5-AG) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of 1,5-Anhydroglucitol (1,5-AG) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 85-101% | 79-94% | 78-101% | 79-96% |
EDTA plasma(n=5) | 80-103% | 81-99% | 93-101% | 82-104% |
heparin plasma(n=5) | 83-97% | 97-104% | 79-95% | 84-99% |
sodium citrate plasma(n=5) | 89-96% | 78-90% | 84-91% | 88-98% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:1,5-AG) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Endocrine | A single dose of dapagliflozin, an SGLT-2 inhibitor, induces higher glycosuria in GCK-and HNF1A-MODY than in type 2 diabetes mellitus pubmed:28593615 |
BioMed Research International | Salivary 1, 5-Anhydroglucitol and Vitamin Levels in Relation to Caries Risk in Children |
Endocrine Journal | Continuous subcutaneous insulin infusion combined with liraglutide reduced glycemic variability and oxidative stress in type 2 diabetes mellitus: a study based on the … Pubmed: 31243192 |
Acta Diabetologica | Modulation of gut microbiota contributes to effects of intensive insulin therapy on intestinal morphological alteration in high-fat-diet-treated mice Pubmed: 31749050 |
Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
CPB046Ge11 | BSA Conjugated 1,5-Anhydroglucitol (1,5-AG) | Immunogen; SDS-PAGE; WB. |
PAB046Ge01 | Polyclonal Antibody to 1,5-Anhydroglucitol (1,5-AG) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
CEB046Ge | ELISA Kit for 1,5-Anhydroglucitol (1,5-AG) | Enzyme-linked immunosorbent assay for Antigen Detection. |
MEB046Ge | Mini Samples ELISA Kit for 1,5-Anhydroglucitol (1,5-AG) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB046Ge | Multiplex Assay Kit for 1,5-Anhydroglucitol (1,5-AG) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSB046Ge11 | ELISA Kit DIY Materials for 1,5-Anhydroglucitol (1,5-AG) | Main materials for "Do It (ELISA Kit) Yourself". |