Multiplex Assay Kit for Low Density Lipoprotein Receptor Related Protein 1 (LRP1) ,etc. by FLIA (Flow Luminescence Immunoassay)

CD91; LRP; A2MR; APOER; APR; TGFBR5; Alpha-2-Macroglobulin Receptor; Prolow-density lipoprotein receptor-related protein 1; Apolipoprotein E receptor

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Low Density Lipoprotein Receptor Related Protein 1 (LRP1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Low Density Lipoprotein Receptor Related Protein 1 (LRP1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Low Density Lipoprotein Receptor Related Protein 1 (LRP1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Low Density Lipoprotein Receptor Related Protein 1 (LRP1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 86-96 89
EDTA plasma(n=5) 80-101 85
heparin plasma(n=5) 96-105 101
sodium citrate plasma(n=5) 99-105 102

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Low Density Lipoprotein Receptor Related Protein 1 (LRP1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Low Density Lipoprotein Receptor Related Protein 1 (LRP1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Low Density Lipoprotein Receptor Related Protein 1 (LRP1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-101% 97-104% 80-89% 96-104%
EDTA plasma(n=5) 88-95% 92-101% 90-97% 83-95%
heparin plasma(n=5) 78-96% 89-99% 92-103% 92-105%
sodium citrate plasma(n=5) 88-99% 79-91% 84-98% 82-89%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:LRP1) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
European Journal of Vascular and Endovascular Surgery Plasma Low-density Lipoprotein Receptor-related Protein 1 Concentration is not Associated with Human Abdominal Aortic Aneurysm Presence Science: Article
Int J Cardiol Circulating soluble low-density lipoprotein receptor-related protein 1 (sLRP1) concentration is associated with hypercholesterolemia: A new potential biomarker for atherosclerosis PubMed: 26285183
International Journal of Cardiology Circulating levels of soluble low-density lipoprotein receptor-related protein 1 (sLRP1) as novel biomarker of epicardial adipose tissue pubmed:27543712
Journal of Cellular and Molecular Medicine Extracellular vesicles do not contribute to higher circulating levels of soluble LRP1 in idiopathic dilated cardiomyopathy doi:10.1111
Scientific Reports Soluble LRP1 is an independent biomarker of epicardial fat volume in patients with type 1 diabetes mellitus Pubmed:29348672
Atherosclerosis Soluble low-density lipoprotein receptor-related protein 1 as a biomarker of coronary risk: Predictive capacity and association with clinical events
Biomedical Reports Gender difference and genetic variance in lipoprotein receptor‑related protein 1 is associated with mortality
biorxiv. CMTM6 drives cisplatin resistance in OSCC by regulating AKT mediated Wnt signaling
JCI Insight CMTM6 drives cisplatin resistance by regulating Wnt signaling through ENO-1/AKT/GSK3¦Â axis 33434185
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPB010Mu02 Recombinant Low Density Lipoprotein Receptor Related Protein 1 (LRP1) Positive Control; Immunogen; SDS-PAGE; WB.
RPB010Mu01 Recombinant Low Density Lipoprotein Receptor Related Protein 1 (LRP1) Positive Control; Immunogen; SDS-PAGE; WB.
PAB010Mu02 Polyclonal Antibody to Low Density Lipoprotein Receptor Related Protein 1 (LRP1) WB; IHC; ICC; IP.
PAB010Mu01 Polyclonal Antibody to Low Density Lipoprotein Receptor Related Protein 1 (LRP1) WB; IHC; ICC; IP.
SEB010Mu ELISA Kit for Low Density Lipoprotein Receptor Related Protein 1 (LRP1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB010Mu Multiplex Assay Kit for Low Density Lipoprotein Receptor Related Protein 1 (LRP1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.