Multiplex Assay Kit for Podocin (PDCN) ,etc. by FLIA (Flow Luminescence Immunoassay)

NPHS2; NPHS-2; Nephrosis 2; Idiopathic Steroid-Resistant

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Podocin (PDCN).
No significant cross-reactivity or interference between Podocin (PDCN) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Podocin (PDCN) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Podocin (PDCN) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:PDCN) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Experimental and molecular pathology Alteration of Connexin43 expression in a rat model of obesity-related glomerulopathy. pubmed:29246788
Journal of Clinical Medicine Multiplex Bead Array Assay of a Panel of Circulating Cytokines and Growth Factors in Patients with Albuminuric and Non-AlbuminuricDiabetic Kidney Disease Pubmed: 32961903
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA938Hu01 Recombinant Podocin (PDCN) Positive Control; Immunogen; SDS-PAGE; WB.
RPA938Hu02 Recombinant Podocin (PDCN) Positive Control; Immunogen; SDS-PAGE; WB.
PAA938Hu01 Polyclonal Antibody to Podocin (PDCN) WB
PAA938Hu02 Polyclonal Antibody to Podocin (PDCN) WB
LAA938Hu71 Biotin-Linked Polyclonal Antibody to Podocin (PDCN) WB; IHC; ICC.
LAA938Hu81 FITC-Linked Polyclonal Antibody to Podocin (PDCN) WB; IHC; ICC; IF.
MAA938Hu22 Monoclonal Antibody to Podocin (PDCN) WB
MAA938Hu23 Monoclonal Antibody to Podocin (PDCN) WB
MAA938Hu21 Monoclonal Antibody to Podocin (PDCN) WB; IHC; ICC; IP.
SEA938Hu ELISA Kit for Podocin (PDCN) Enzyme-linked immunosorbent assay for Antigen Detection.
AEA938Hu ELISA Kit for Anti-Podocin Antibody (Anti-PDCN) Enzyme-linked immunosorbent assay for Antibody Detection.
CMA938Hu Multiplex Assay Kit for Podocin (PDCN) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMA938Hu Multiplex Assay Kit for Podocin (PDCN) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA938Hu01 ELISA Kit DIY Materials for Podocin (PDCN) Main materials for "Do It (ELISA Kit) Yourself".