Multiplex Assay Kit for Complement Receptor 2 (CD21) ,etc. by FLIA (Flow Luminescence Immunoassay)

CR2; C3DR; Complement Component(3d/Epstein Barr Virus)Receptor 2; Complement C3d receptor; Epstein-Barr virus receptor; EBV receptor

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Complement Receptor 2 (CD21) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Complement Receptor 2 (CD21) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Complement Receptor 2 (CD21) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Complement Receptor 2 (CD21) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-103 97
EDTA plasma(n=5) 85-103 99
heparin plasma(n=5) 80-99 88
sodium citrate plasma(n=5) 95-103 99

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement Receptor 2 (CD21) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement Receptor 2 (CD21) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Complement Receptor 2 (CD21) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-92% 83-91% 96-105% 89-97%
EDTA plasma(n=5) 80-97% 84-98% 82-91% 78-93%
heparin plasma(n=5) 90-104% 97-104% 97-105% 92-105%
sodium citrate plasma(n=5) 93-101% 90-99% 95-105% 82-97%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CD21) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
journal of neuroinflammation Complement receptor 2 is up regulated in the spinal cord following nerve root injury and modulates the spinal cord response PubMed: 26502875
Clin Immunol Complement Receptor 2 is increased in cerebrospinal fluid of multiple sclerosis patients and reCavia (Guinea pig )lates C3 function Pubmed:27085202
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA750Hu01 Recombinant Complement Receptor 2 (CD21) Positive Control; Immunogen; SDS-PAGE; WB.
PAA750Hu01 Polyclonal Antibody to Complement Receptor 2 (CD21) WB; IHC; ICC; IP.
FAA750Hu01 Anti-Complement Receptor 2 (CD21) Polyclonal Antibody Flow cytometry.
MAA750Hu23 Monoclonal Antibody to Complement Receptor 2 (CD21) WB; IHC; ICC; IP.
MAA750Hu25 Monoclonal Antibody to Complement Receptor 2 (CD21) WB; IHC; ICC; IP.
MAA750Hu21 Monoclonal Antibody to Complement Receptor 2 (CD21) WB; IHC; ICC; IP.
MAA750Hu24 Monoclonal Antibody to Complement Receptor 2 (CD21) WB; IHC; ICC; IP.
MAA750Hu22 Monoclonal Antibody to Complement Receptor 2 (CD21) WB; IHC; ICC; IP.
SEA750Hu ELISA Kit for Complement Receptor 2 (CD21) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA750Hu Multiplex Assay Kit for Complement Receptor 2 (CD21) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.