Multiplex Assay Kit for Free Thyroxine (fT4) ,etc. by FLIA (Flow Luminescence Immunoassay)
FTI
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA185Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range0.09-90pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.03 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 382
US$ 396
US$ 418
US$ 448
US$ 477
US$ 521
US$ 587
Result
For more details, please contact local distributors! US$ 734 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Free Thyroxine (fT4) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Free Thyroxine (fT4) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Free Thyroxine (fT4) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Free Thyroxine (fT4) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 80-93 | 90 |
EDTA plasma(n=5) | 91-98 | 94 |
heparin plasma(n=5) | 93-105 | 101 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Free Thyroxine (fT4) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Free Thyroxine (fT4) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Free Thyroxine (fT4) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 91-98% | 78-96% | 78-97% | 97-105% |
EDTA plasma(n=5) | 92-105% | 80-104% | 95-102% | 88-102% |
heparin plasma(n=5) | 98-105% | 80-97% | 87-101% | 91-99% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:fT4) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Frontiers in cellular neuroscience | Elevated Thyroid Peroxidase Antibody Increases Risk of Post-partum Depression by Decreasing Prefrontal Cortex BDNF and 5-HT Levels in Mice pubmed:28119573 |
ARC Journal of Nutrition and Growth | Effect of Selenium and Zinc Supplementation on Hypothyroidism in Rats ISSN 2455-2550 |
Frontiers in Neuroscience | Modulation of Calcitonin, Parathyroid Hormone, and Thyroid Hormone Secretion by Electrical Stimulation of Sympathetic and Parasympathetic Nerves in Anesthetized Rats. pubmed:28713236 |
Brain Research | Age-Dependent Evaluation of Long-Term Depression Responses in Hyperthyroid Rats: Possible Roles of Oxidative Intracellular Redox Status Pubmed: 31288003 |
Journal of Physiological Sciences | Thyroxin and calcitonin secretion into thyroid venous blood is regulated by pharyngeal mechanical stimulation in anesthetized rats Pubmed: 31270742 |
International Journal of Clinical and Experimental Medicine | Apatinib inhibits proliferation of different lung cancer cells in vitro and in vivo by promoting apoptosis and inducing cell cycle arrest |
Int J Dev Neurosci | Effect of L©\thyroxine administration on long©\term potentiation and accompanying mitogen©\activated protein kinases in rats 33576121 |
Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
IEA185Ge | Instant ELISA Kit for Free Thyroxine (fT4) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEA185Ge | ELISA Kit for Free Thyroxine (fT4) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CCA185Ge | CLIA Kit for Free Thyroxine (fT4) | Chemiluminescent immunoassay for Antigen Detection. |
LMA185Ge | Multiplex Assay Kit for Free Thyroxine (fT4) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |