Multiplex Assay Kit for Free Thyroxine (fT4) ,etc. by CBA (Cytometric Bead Array)
FTI
- Product No.CMA185Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length3h
- Detection Range0.0879-90pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.0293pg/mL.
- DownloadInstruction Manual
- UOM 48T96T
- FOB
US$ 514
US$ 734
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Free Thyroxine (fT4) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Free Thyroxine (fT4) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Free Thyroxine (fT4) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Free Thyroxine (fT4) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 85-94 | 89 |
| EDTA plasma(n=5) | 97-105 | 101 |
| heparin plasma(n=5) | 80-99 | 90 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Free Thyroxine (fT4) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Free Thyroxine (fT4) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Free Thyroxine (fT4) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 95-105% | 78-90% | 91-98% | 97-105% |
| EDTA plasma(n=5) | 93-103% | 88-102% | 79-104% | 95-103% |
| heparin plasma(n=5) | 82-89% | 78-98% | 85-98% | 95-105% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:fT4) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations |
| Frontiers in cellular neuroscience | Elevated Thyroid Peroxidase Antibody Increases Risk of Post-partum Depression by Decreasing Prefrontal Cortex BDNF and 5-HT Levels in Mice pubmed:28119573 |
| ARC Journal of Nutrition and Growth | Effect of Selenium and Zinc Supplementation on Hypothyroidism in Rats ISSN 2455-2550 |
| Frontiers in Neuroscience | Modulation of Calcitonin, Parathyroid Hormone, and Thyroid Hormone Secretion by Electrical Stimulation of Sympathetic and Parasympathetic Nerves in Anesthetized Rats. pubmed:28713236 |
| Brain Research | Age-Dependent Evaluation of Long-Term Depression Responses in Hyperthyroid Rats: Possible Roles of Oxidative Intracellular Redox Status Pubmed: 31288003 |
| Journal of Physiological Sciences | Thyroxin and calcitonin secretion into thyroid venous blood is regulated by pharyngeal mechanical stimulation in anesthetized rats Pubmed: 31270742 |
| International Journal of Clinical and Experimental Medicine | Apatinib inhibits proliferation of different lung cancer cells in vitro and in vivo by promoting apoptosis and inducing cell cycle arrest |
| Int J Dev Neurosci | Effect of L©\thyroxine administration on long©\term potentiation and accompanying mitogen©\activated protein kinases in rats 33576121 |
| Catalog No. | Related products for research use of Pan-species (General) Organism species | Applications (RESEARCH USE ONLY!) |
| IEA185Ge | Instant ELISA Kit for Free Thyroxine (fT4) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| CEA185Ge | ELISA Kit for Free Thyroxine (fT4) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| CCA185Ge | CLIA Kit for Free Thyroxine (fT4) | Chemiluminescent immunoassay for Antigen Detection. |
| CMA185Ge | Multiplex Assay Kit for Free Thyroxine (fT4) ,etc. by CBA (Cytometric Bead Array) | FLIA Kit for Antigen Detection. |
| LMA185Ge | Multiplex Assay Kit for Free Thyroxine (fT4) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |