Multiplex Assay Kit for Collagen Type IV Alpha 1 (COL4a1) ,etc. by FLIA (Flow Luminescence Immunoassay)
COL4-A1; Arresten; Collagen Alpha-1(IV)chain
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA149Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range0.29-300ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.097 ng/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 393
US$ 408
US$ 431
US$ 461
US$ 491
US$ 537
US$ 605
Result
For more details, please contact local distributors! US$ 756 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Collagen Type IV Alpha 1 (COL4a1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Collagen Type IV Alpha 1 (COL4a1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Collagen Type IV Alpha 1 (COL4a1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Collagen Type IV Alpha 1 (COL4a1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 88-96 | 92 |
EDTA plasma(n=5) | 95-102 | 98 |
heparin plasma(n=5) | 83-97 | 89 |
sodium citrate plasma(n=5) | 96-103 | 99 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Collagen Type IV Alpha 1 (COL4a1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Collagen Type IV Alpha 1 (COL4a1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Collagen Type IV Alpha 1 (COL4a1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 98-105% | 98-105% | 84-101% | 87-101% |
EDTA plasma(n=5) | 82-101% | 80-91% | 92-105% | 87-104% |
heparin plasma(n=5) | 78-92% | 84-101% | 80-88% | 83-91% |
sodium citrate plasma(n=5) | 85-92% | 80-98% | 88-99% | 79-103% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:COL4a1) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Cancer Research | Peritoneal Dissemination Requires an Sp1-Dependent CXCR4/CXCL12 Signaling Axis and Extracellular MatrixâDirected Spheroid Formation Pubmed:26744523 |
PLoS One | miR-146a regulates glucose induced upregulation of inflammatory cytokines extracellular matrix proteins in the retina and kidney in diabetes 10.1371 |
Journal of Diabetes & Metabolic Disorders | Endothelin-1 traps potently reduce pathologic markers back to basal levels in an in vitro model of diabetes |
Experimental and Molecular Pathology | Epitope recognized by anti-glomerular basement membrane (GBM) antibody in a patient with repeated relapse of anti-GBM disease Pubmed: 30817909 |
Journal of Diabetes & Metabolic Disorders | In vivo studies demonstrate that endothelin-1 traps are a potential therapy for type I diabetes |
Frontiers in Endocrinology | Curcumin Analogs Reduce Stress and Inflammation Indices in Experimental Models of Diabetes Pubmed: 31920992 |