Multiplex Assay Kit for Plasminogen Activator, Urokinase Receptor (uPAR) ,etc. by FLIA (Flow Luminescence Immunoassay)
CD87; PLAUR; PLAU-R; U-PAR; URKR; Monocyte Activation Antigen Mo3
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA141Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample Typeserum, plasma, tissue homogenates and other biological fluids
- Test MethodDouble-antibody Sandwich
- Assay Length3.5h
- Detection Range4.88-5000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 1.627 pg/mL.
- DownloadInstruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
- FOB
US$ 405
US$ 420
US$ 443
US$ 475
US$ 506
US$ 552
US$ 622
Result
For more details, please contact local distributors! US$ 778 Add to Price Calculator
Specificity
This assay has high sensitivity and excellent specificity for detection of Plasminogen Activator, Urokinase Receptor (uPAR) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Plasminogen Activator, Urokinase Receptor (uPAR) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Plasminogen Activator, Urokinase Receptor (uPAR) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Plasminogen Activator, Urokinase Receptor (uPAR) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 83-90 | 86 |
EDTA plasma(n=5) | 79-101 | 82 |
heparin plasma(n=5) | 91-99 | 94 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Plasminogen Activator, Urokinase Receptor (uPAR) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Plasminogen Activator, Urokinase Receptor (uPAR) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Plasminogen Activator, Urokinase Receptor (uPAR) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 78-89% | 92-99% | 98-105% | 96-103% |
EDTA plasma(n=5) | 80-91% | 81-102% | 80-98% | 86-101% |
heparin plasma(n=5) | 83-98% | 97-105% | 78-92% | 82-92% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
96-well plate | 1 | Plate sealer for 96 wells | 4 |
Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
Pre-Mixed Magnetic beads (22#:uPAR) | 1 | Analysis buffer | 1×20mL |
Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
Instruction manual | 1 |
Assay procedure summary
1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
International Journal of Cancer | Dietary supplementation with methylseleninic acid, but not selenomethionine, reduces spontaneous metastasis of Lewis lung carcinoma in mice Wiley: source |
Biomark Insights | Decreased Epidermal Growth Factor (EGF) Associated with HMGB1 and Increased Hyperactivity in Children with Autism PubMed: PMC3623607 |
Biomarker insights | Decreased Hepatocyte Growth Factor (HGF) and Gamma Aminobutyric Acid (GABA) in Individuals with Obsessive-Compulsive Disorder (OCD) PubMed: PMC3762604 |
Am J Emerg Med | Clinical value of soluble urokinase-type plasminogen activator receptor in the diagnosis, prognosis, and therapeutic guidance of sepsis PubMed: 26615223 |
Archives of Clinical Infectious Diseases | Evaluation of Diagnostic Value of Soluble Urokinase-Type Plasminogen Activator Receptor in Sepsis Archcid: 26346 |
The American Journal of Emergency Medicine | Clinical value of soluble urokinase-type plasminogen activator receptor in the diagnosis, prognosis, and therapeutic Cavia (Guinea pig )idance of sepsis science:S0735675715009559 |
Journal of Clinical and Experimental Hepatology | Evaluation of Plasma Urokinase-Type Plasminogen Activator Receptor (UPAR) in Patients With Chronic Hepatitis B, C and Non-Alcoholic Fatty Liver Disease (NAFLD) … 10.1016:j.jceh.2018.02.001 |
Turkish journal of trauma & emergency surgery | The diagnostic value of serum urokinase-type plasminogen activator receptor in acute appendicitis Pubmed: 31475329 |
CELL TRANSPLANTATION | Predictive Value of Degranulating Factors of Neutrophils in Massive Cerebral Infarction 33787356 |