Multiplex Assay Kit for Interleukin 15 (IL15) ,etc. by FLIA (Flow Luminescence Immunoassay)

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Interleukin 15 (IL15).
No significant cross-reactivity or interference between Interleukin 15 (IL15) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Interleukin 15 (IL15) and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 15 (IL15) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-103 98
EDTA plasma(n=5) 83-92 89
heparin plasma(n=5) 80-104 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 15 (IL15) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 15 (IL15) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 15 (IL15) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-101% 78-89% 93-101% 97-105%
EDTA plasma(n=5) 91-102% 89-103% 81-97% 84-103%
heparin plasma(n=5) 82-104% 91-105% 85-92% 96-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:IL15) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Endocrine Expression of interleukin-15 and inflammatory cytokines in skeletal muscles of STZ-induced diabetic rats: effect of resistance exercise training Pubmed: 24006180
Endocrine Time course of IL-15 expression after acute resistance exercise in trained rats: effect of diabetes and skeletal muscle phenotype Pubmed:25522723
Med Sci Moni miR-15b is Downregulated in Myasthenia Gravis Patients and Directly Regulates the Expression of Interleukin-15 (IL-15) in Experimental Myasthenia Gravis Mice PubMed: 26087886
Exercise physiology Effects of intrinsic aerobic capacity, aging and physical activity on interleukin-15 protein level in serum and skeletal muscle Dspace: Handle
Biotechnology Letters Novel adjuvant for immunization against tuberculosis: DNA vaccine expressing Mycobacterium tuberculosis antigen 85A and interleukin-15 fusion product elicits strong immune responses in mice s10529-017-2342-1
Journal of Controlled Release Interleukin-15 and cisplatin co-encapsulated thermosensitive polypeptide hydrogels for combined immuno-chemotherapy. pubmed:28408199
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPA061Mu02 Recombinant Interleukin 15 (IL15) Positive Control; Immunogen; SDS-PAGE; WB.
RPA061Mu01 Recombinant Interleukin 15 (IL15) Positive Control; Immunogen; SDS-PAGE; WB.
APA061Mu01 Active Interleukin 15 (IL15) Cell culture; Activity Assays.
EPA061Mu61 Eukaryotic Interleukin 15 (IL15) Positive Control; Immunogen; SDS-PAGE; WB.
PAA061Mu01 Polyclonal Antibody to Interleukin 15 (IL15) WB
PAA061Mu02 Polyclonal Antibody to Interleukin 15 (IL15) WB; IHC; ICC; IP.
LAA061Mu71 Biotin-Linked Polyclonal Antibody to Interleukin 15 (IL15) WB; IHC; ICC.
LAA061Mu81 FITC-Linked Polyclonal Antibody to Interleukin 15 (IL15) WB; IHC; ICC; IF.
SEA061Mu ELISA Kit for Interleukin 15 (IL15) Enzyme-linked immunosorbent assay for Antigen Detection.
MEA061Mu Mini Samples ELISA Kit for Interleukin 15 (IL15) Enzyme-linked immunosorbent assay for Antigen Detection.
CMA061Mu Multiplex Assay Kit for Interleukin 15 (IL15) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMA061Mu Multiplex Assay Kit for Interleukin 15 (IL15) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA061Mu01 ELISA Kit DIY Materials for Interleukin 15 (IL15) Main materials for "Do It(ELISA Kit) Yourself"