Multiplex Assay Kit for Activating Signal Cointegrator 1 Complex Subunit 3 (ASCC3) ,etc. by CBA (Cytometric Bead Array)

HELIC1; RNAH; ASC1p200; RNA Helicase Family; Helicase, ATP Binding 1; Trip4 complex subunit p200; ASC-1 complex subunit p200

Specificity

This assay has high sensitivity and excellent specificity for detection of Activating Signal Cointegrator 1 Complex Subunit 3 (ASCC3) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Activating Signal Cointegrator 1 Complex Subunit 3 (ASCC3) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Activating Signal Cointegrator 1 Complex Subunit 3 (ASCC3) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Activating Signal Cointegrator 1 Complex Subunit 3 (ASCC3) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-101 97
EDTA plasma(n=5) 98-105 101
heparin plasma(n=5) 82-103 99

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Activating Signal Cointegrator 1 Complex Subunit 3 (ASCC3) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Activating Signal Cointegrator 1 Complex Subunit 3 (ASCC3) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Activating Signal Cointegrator 1 Complex Subunit 3 (ASCC3) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-103% 99-105% 78-103% 80-96%
EDTA plasma(n=5) 81-89% 96-105% 84-93% 96-103%
heparin plasma(n=5) 98-105% 94-101% 78-101% 85-102%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Toxicology Letters miR-3940-5p associated with genetic damage in workers exposed to hexavalent chromium Pubmed:24973494
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPQ709Hu01 Recombinant Activating Signal Cointegrator 1 Complex Subunit 3 (ASCC3) Positive Control; Immunogen; SDS-PAGE; WB.
PAQ709Hu01 Polyclonal Antibody to Activating Signal Cointegrator 1 Complex Subunit 3 (ASCC3) WB; IHC; ICC; IP.
MAQ709Hu21 Monoclonal Antibody to Activating Signal Cointegrator 1 Complex Subunit 3 (ASCC3) WB; IHC; ICC; IP.
SEQ709Hu ELISA Kit for Activating Signal Cointegrator 1 Complex Subunit 3 (ASCC3) Enzyme-linked immunosorbent assay for Antigen Detection.
LMQ709Hu Multiplex Assay Kit for Activating Signal Cointegrator 1 Complex Subunit 3 (ASCC3) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMQ709Hu Multiplex Assay Kit for Activating Signal Cointegrator 1 Complex Subunit 3 (ASCC3) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.