Multiplex Assay Kit for Potassium Chloride Cotransporters 1 (KCC1) ,etc. by CBA (Cytometric Bead Array)

SLC12A4; hKCC1; Solute Carrier Family 12 Member 4,Potassium/Chloride Transporters; Chloride Potassium Symporter 4; Electroneutral potassium-chloride cotransporter 1

Specificity

This assay has high sensitivity and excellent specificity for detection of Potassium Chloride Cotransporters 1 (KCC1) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Potassium Chloride Cotransporters 1 (KCC1) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Potassium Chloride Cotransporters 1 (KCC1) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Potassium Chloride Cotransporters 1 (KCC1) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 81-102 85
EDTA plasma(n=5) 87-104 97
heparin plasma(n=5) 80-88 81

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Potassium Chloride Cotransporters 1 (KCC1) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Potassium Chloride Cotransporters 1 (KCC1) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Potassium Chloride Cotransporters 1 (KCC1) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 83-94% 92-105% 89-97% 90-97%
EDTA plasma(n=5) 95-102% 88-103% 97-105% 87-101%
heparin plasma(n=5) 84-104% 86-94% 90-103% 98-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Scientific Reports MicroRNA-127 targeting of mitoNEET inhibits neurite outgrowth, induces cell apoptosis and contributes to physiological dysfunction after spinal cord transection pubmed:27748416
FASEB Journal Altered levels of plasma neuron-derived exosomes and their cargo proteins characterize acute and chronic mild traumatic brain injury Pubmed: 30605353
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
SEE376Ra ELISA Kit for Potassium Chloride Cotransporters 1 (KCC1) Enzyme-linked immunosorbent assay for Antigen Detection.
CME376Ra Multiplex Assay Kit for Potassium Chloride Cotransporters 1 (KCC1) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LME376Ra Multiplex Assay Kit for Potassium Chloride Cotransporters 1 (KCC1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.