Multiplex Assay Kit for Integrin Beta 6 (ITGb6) ,etc. by CBA (Cytometric Bead Array)

ITG-B6

Specificity

This assay has high sensitivity and excellent specificity for detection of Integrin Beta 6 (ITGb6) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Integrin Beta 6 (ITGb6) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Integrin Beta 6 (ITGb6) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Integrin Beta 6 (ITGb6) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 91-105 101
EDTA plasma(n=5) 81-104 85
heparin plasma(n=5) 94-102 99

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Integrin Beta 6 (ITGb6) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Integrin Beta 6 (ITGb6) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Integrin Beta 6 (ITGb6) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-91% 89-103% 81-88% 84-98%
EDTA plasma(n=5) 87-101% 97-105% 95-103% 82-93%
heparin plasma(n=5) 87-95% 90-98% 79-104% 87-95%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Intergrin alpha v beta 6 for diagnosis/prognosis of colorectal carcinoma :
International Journal of Cancer β‐Integrin serves as a novel serum tumor marker for colorectal carcinoma Pubmed: 30653264
Clin Transl Gastroenterol β6-Integrin Serves as a Potential Serum Marker for Diagnosis and Prognosis of Pancreatic Adenocarcinoma 34388137
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC099Hu01 Recombinant Integrin Beta 6 (ITGb6) Positive Control; Immunogen; SDS-PAGE; WB.
PAC099Hu01 Polyclonal Antibody to Integrin Beta 6 (ITGb6) WB; IHC; ICC/IF
MAC099Hu22 Monoclonal Antibody to Integrin Beta 6 (ITGb6) WB
MAC099Hu21 Monoclonal Antibody to Integrin Beta 6 (ITGb6) WB
MAC099Hu23 Monoclonal Antibody to Integrin Beta 6 (ITGb6) WB
SEC099Hu ELISA Kit for Integrin Beta 6 (ITGb6) Enzyme-linked immunosorbent assay for Antigen Detection.
SCC099Hu CLIA Kit for Integrin Beta 6 (ITGb6) Chemiluminescent immunoassay for Antigen Detection.
LMC099Hu Multiplex Assay Kit for Integrin Beta 6 (ITGb6) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMC099Hu Multiplex Assay Kit for Integrin Beta 6 (ITGb6) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.