Multiplex Assay Kit for Farnesoid X Receptor (FXR) ,etc. by CBA (Cytometric Bead Array)

NR1H4; BAR; FXR; HRR1; RIP14; Nuclear Receptor Subfamily 1,Group H,Member 4; Bile acid receptor; Farnesol receptor HRR-1; Retinoid X receptor-interacting protein 14

Specificity

This assay has high sensitivity and excellent specificity for detection of Farnesoid X Receptor (FXR) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Farnesoid X Receptor (FXR) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Farnesoid X Receptor (FXR) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Farnesoid X Receptor (FXR) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-101 96
EDTA plasma(n=5) 84-95 89
heparin plasma(n=5) 82-92 86

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Farnesoid X Receptor (FXR) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Farnesoid X Receptor (FXR) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Farnesoid X Receptor (FXR) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 92-103% 83-103% 92-101% 80-101%
EDTA plasma(n=5) 92-104% 96-105% 93-101% 79-105%
heparin plasma(n=5) 78-101% 90-99% 92-101% 86-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
The Journal of Nutritional Biochemistry Raspberry pomace alters cecal microbial activity and reduces secondary bile acids in rats fed a high-fat diet. pubmed:28437712
Chinese Journal of Natural Medicines Hypolipidemic effect of SIPI-7623, a derivative of an extract from oriental wormwood, through farnesoid X receptor antagonism Pubmed: 30197122
Cytotechnology d-Allulose enhances uptake of HDL-cholesterol into rat's primary hepatocyte via SR-B1 Pubmed: 32086695
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC042Hu01 Recombinant Farnesoid X Receptor (FXR) Positive Control; Immunogen; SDS-PAGE; WB.
PAC042Hu01 Polyclonal Antibody to Farnesoid X Receptor (FXR) WB
MAC042Hu22 Monoclonal Antibody to Farnesoid X Receptor (FXR) WB; IHC; ICC; IP.
SEC042Hu ELISA Kit for Farnesoid X Receptor (FXR) Enzyme-linked immunosorbent assay for Antigen Detection.
CMC042Hu Multiplex Assay Kit for Farnesoid X Receptor (FXR) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMC042Hu Multiplex Assay Kit for Farnesoid X Receptor (FXR) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.