Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
Multiplex Assay Kit for Hemojuvelin (HJV) ,etc. by CBA (Cytometric Bead Array)
HFE2; HFE2A; HJV; JH; RGMC; hemochromatosis type 2(Juvenile); Haemojuvelin; RGM domain family member C
- Product No.CMB995Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length3h
- Detection Range0.9766-1000ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.3255ng/mL.
- DownloadInstruction Manual
- UOM 48T96T
- FOB
US$ 571
US$ 816
For more details, please contact local distributors!
Specificity
This assay has high sensitivity and excellent specificity for detection of Hemojuvelin (HJV) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Hemojuvelin (HJV) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Hemojuvelin (HJV) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Hemojuvelin (HJV) ,etc. by CBA (Cytometric Bead Array) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 96-105 | 101 |
| EDTA plasma(n=5) | 95-104 | 101 |
| heparin plasma(n=5) | 85-99 | 91 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Hemojuvelin (HJV) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Hemojuvelin (HJV) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Hemojuvelin (HJV) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 97-105% | 84-93% | 86-94% | 89-96% |
| EDTA plasma(n=5) | 78-89% | 80-88% | 78-102% | 83-92% |
| heparin plasma(n=5) | 79-101% | 93-101% | 99-105% | 86-98% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
| Reagents | Quantity | Reagents | Quantity |
| 96-well plate | 1 | Plate sealer for 96 wells | 4 |
| Pre-Mixed Standard | 2 | Standard Diluent | 1×20mL |
| Pre-Mixed Magnetic beads (22#:HJV) | 1 | Analysis buffer | 1×20mL |
| Pre-Mixed Detection Reagent A | 1×120μL | Assay Diluent A | 1×12mL |
| Detection Reagent B (PE-SA) | 1×120μL | Assay Diluent B | 1×12mL |
| Sheath Fluid | 1×10mL | Wash Buffer (30 × concentrate) | 1×20mL |
| Instruction manual | 1 |
Assay procedure summary
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
GIVEAWAYS
INCREMENT SERVICES
| Magazine | Citations |
| PLoS One. | Effect of Iron Overload and Iron Deficiency on Liver Hemojuvelin Protein PubMed: PMC3356351 |
| Journal of | Hepcidin Levels Are Increased in Patients with Acute Ischemic Stroke: Preliminary Report PubMed: 25881778 |
| European Journal of Haematology | Soluble hemojuvelin in transfused and untransfused thalassaemic subjects doi:10.1111 |
| American Journal of Nephrology | The secret war against counterfeit science pubmed:28492262 |
| Critical Care | Urinary biomarkers predict advanced acute kidney injury after cardiovascular surgery Pubmed:29699579 |
| Scientific Reports | Hemojuvelin Predicts Acute Kidney Injury and Poor Outcomes Following Cardiac Surgery Pubmed:29386545 |
| Journal of Cerebral Blood Flow and Metabolism | The functional role of hemojuvelin in acute ischemic stroke Pubmed: 31307288 |
| Oxidative damage and iron dyshomeostasis in thalassemic patients | |
| J Trace Elem Med Biol | Caffeine and alcohol-friends or foes of human iron stores? Pubmed:35063815 |
| Arch Pathol Lab Med | Urinary Biomarkers Can Predict Weaning From Acute Dialysis Therapy in Critically Ill Patients Pubmed:35311928 |
| Arch Pathol Lab Med | The Relationships among Plasma Fetuin-B, Thyroid Autoimmunity, and Fertilization Rate In Vitro Fertilization and Embryo Transfer Pubmed:35340679 |

