Multiplex Assay Kit for Netrin 4 (Ntn4) ,etc. by CBA (Cytometric Bead Array)

Beta-Netrin; Hepar-derived netrin-like protein

Specificity

This assay has high sensitivity and excellent specificity for detection of Netrin 4 (Ntn4) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Netrin 4 (Ntn4) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Netrin 4 (Ntn4) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Netrin 4 (Ntn4) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 94-102 98
EDTA plasma(n=5) 85-92 89
heparin plasma(n=5) 96-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Netrin 4 (Ntn4) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Netrin 4 (Ntn4) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Netrin 4 (Ntn4) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-95% 87-101% 93-103% 82-97%
EDTA plasma(n=5) 96-105% 95-105% 86-103% 95-104%
heparin plasma(n=5) 84-96% 91-99% 96-105% 91-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Journal of Maternal-Fetal and Neonatal Medicine Cord blood netrin-1 and -4 concentrations in term pregnancies with normal, restricted and increased fetal growth Informahealthcare: Source
J Matern?Fetal?Neonatal Med.? Cord blood netrin-1 and-4 concentrations in term pregnancies with normal, restricted and increased fetal growth Pubmed:24716747
International Journal of Molecular Sciences Transcriptomic and Proteomic Analyses Reveal the Potential Mode of Action of Chondrocyte Sheets in Hyaline Cartilage Regeneration Pubmed: 31878307
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB835Hu01 Recombinant Netrin 4 (Ntn4) Positive Control; Immunogen; SDS-PAGE; WB.
PAB835Hu01 Polyclonal Antibody to Netrin 4 (Ntn4) IHC
MAB835Hu22 Monoclonal Antibody to Netrin 4 (Ntn4) WB; IHC; ICC; IP.
SEB835Hu ELISA Kit for Netrin 4 (Ntn4) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB835Hu Multiplex Assay Kit for Netrin 4 (Ntn4) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMB835Hu Multiplex Assay Kit for Netrin 4 (Ntn4) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.