Multiplex Assay Kit for Cholesteryl Ester Transfer Protein (CETP) ,etc. by CBA (Cytometric Bead Array)

LTP; Lipid Transfer Protein; Plasma Lipid Transfer Protein; Cholesterylester Transfer Protein

Specificity

This assay has high sensitivity and excellent specificity for detection of Cholesteryl Ester Transfer Protein (CETP) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Cholesteryl Ester Transfer Protein (CETP) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Cholesteryl Ester Transfer Protein (CETP) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Cholesteryl Ester Transfer Protein (CETP) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 86-101 96
EDTA plasma(n=5) 88-96 92
heparin plasma(n=5) 88-96 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cholesteryl Ester Transfer Protein (CETP) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cholesteryl Ester Transfer Protein (CETP) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cholesteryl Ester Transfer Protein (CETP) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 93-101% 80-89% 80-95% 87-104%
EDTA plasma(n=5) 80-95% 79-103% 99-105% 93-105%
heparin plasma(n=5) 90-97% 95-105% 80-91% 91-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Neurotoxicology. 27-Hydroxycholesterol regulates cholesterol synthesis and transport in C6 glioma cells. pubmed:28167099
Nutrition A baru almond-enriched diet reduces abdominal adiposity and improves HDL concentrations: A randomized, placebo-controlled trial Pubmed:30086484
Scientific Reports CETP genetic variant rs1800777 (allele A) is associated with abnormally low HDL-C levels and increased risk of AKI during sepsis Pubmed: 30425299
Nutrition A baru almond└ enriched diet reduces abdominal adiposity and improves high-density lipoprotein concentrations: a randomized, placebo-controlled trial Pubmed: 30086484
Laboratory medicine Association of Serum Cholesterol Ester Transfer Protein Levels with Taq IB Polymorphism in Acute Coronary Syndrome Pubmed: 31504738
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA814Hu01 Recombinant Cholesteryl Ester Transfer Protein (CETP) Positive Control; Immunogen; SDS-PAGE; WB.
RPA814Hu02 Recombinant Cholesteryl Ester Transfer Protein (CETP) Positive Control; Immunogen; SDS-PAGE; WB.
RPA814Hu03 Recombinant Cholesteryl Ester Transfer Protein (CETP) Positive Control; Immunogen; SDS-PAGE; WB.
RPA814Hu04 Recombinant Cholesteryl Ester Transfer Protein (CETP) Positive Control; Immunogen; SDS-PAGE; WB.
PAA814Hu02 Polyclonal Antibody to Cholesteryl Ester Transfer Protein (CETP) WB; IHC; ICC/IF
PAA814Hu01 Polyclonal Antibody to Cholesteryl Ester Transfer Protein (CETP) IHC
PAA814Hu03 Polyclonal Antibody to Cholesteryl Ester Transfer Protein (CETP) Testing in progress
LAA814Hu71 Biotin-Linked Polyclonal Antibody to Cholesteryl Ester Transfer Protein (CETP) WB; IHC; ICC.
MAA814Hu22 Monoclonal Antibody to Cholesteryl Ester Transfer Protein (CETP) WB; IHC; ICC; IP.
SEA814Hu ELISA Kit for Cholesteryl Ester Transfer Protein (CETP) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA814Hu Multiplex Assay Kit for Cholesteryl Ester Transfer Protein (CETP) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMA814Hu Multiplex Assay Kit for Cholesteryl Ester Transfer Protein (CETP) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.