Multiplex Assay Kit for Myoglobin (MYO) ,etc. by CBA (Cytometric Bead Array)

PVALB; MB

Specificity

This assay has high sensitivity and excellent specificity for detection of Myoglobin (MYO) ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between Myoglobin (MYO) ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Myoglobin (MYO) ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of Myoglobin (MYO) ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-95 84
EDTA plasma(n=5) 91-99 96
heparin plasma(n=5) 95-105 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Myoglobin (MYO) ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Myoglobin (MYO) ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Myoglobin (MYO) ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-101% 96-103% 98-105% 82-89%
EDTA plasma(n=5) 84-94% 94-102% 80-104% 84-103%
heparin plasma(n=5) 99-105% 82-94% 93-105% 92-99%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
European Journal of Applied Physiology Acute leukocyte, cytokine and adipocytokine responses to maximal and hypertrophic resistance exercise bouts Pubmed:25145982
International Journal of Molecular Sciences Transcriptional Alterations by Ischaemic Postconditioning in a Pig Infarction Model: Impact on Microvascular Protection Pubmed: 30650650
BIOSENS BIOELECTRON Electrochemical dual-aptamer-based biosensor for nonenzymatic detection of cardiac troponin I by nanohybrid electrocatalysts labeling combined with DNA … Pubmed: 30954926
Mikrochim Acta DNA nanotetrahedron linked dual-aptamer based voltammetric aptasensor for cardiac troponin I using a magnetic metal-organic framework as a label Pubmed: 31123904
ACS Appl Mater Interfaces Emitter–Quencher Pair of Single Atomic Co Sites and Monolayer Titanium Carbide MXenes for Luminol Chemiluminescent Reactions 34914377
Talanta A rapid fluorescent aptasensor for point-of-care detection of C-reactive protein Pubmed:35714415
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPA480Hu01 Recombinant Myoglobin (MYO) Positive Control; Immunogen; SDS-PAGE; WB.
RPA480Hu02 Recombinant Myoglobin (MYO) Positive Control; Immunogen; SDS-PAGE; WB.
APA480Hu01 Active Myoglobin (MYO) Cell culture; Activity Assays.
PAA480Hu01 Polyclonal Antibody to Myoglobin (MYO) WB; IHC
PAA480Hu02 Polyclonal Antibody to Myoglobin (MYO) Testing in progress
LAA480Hu81 FITC-Linked Polyclonal Antibody to Myoglobin (MYO) WB; IHC; ICC; IF.
LAA480Hu71 Biotin-Linked Polyclonal Antibody to Myoglobin (MYO) WB; IHC; ICC.
MAA480Hu26 Monoclonal Antibody to Myoglobin (MYO) WB; IHC
MAA480Hu28 Monoclonal Antibody to Myoglobin (MYO) WB,IHC
MAA480Hu23 Monoclonal Antibody to Myoglobin (MYO) WB; IHC
MAA480Hu21 Monoclonal Antibody to Myoglobin (MYO) WB; IHC
MAA480Hu25 Monoclonal Antibody to Myoglobin (MYO) WB; IHC
MAA480Hu24 Monoclonal Antibody to Myoglobin (MYO) WB; IHC
MAA480Hu27 Monoclonal Antibody to Myoglobin (MYO) WB; IHC
MAA480Hu29 Monoclonal Antibody to Myoglobin (MYO) WB; IHC
MAA480Hu22 Monoclonal Antibody to Myoglobin (MYO) WB; IHC
FAA480Hu06 Anti-Myoglobin (MYO) Monoclonal Antibody FCM
FAA480Hu04 Anti-Myoglobin (MYO) Monoclonal Antibody FCM
FAA480Hu02 Anti-Myoglobin (MYO) Monoclonal Antibody FCM
OEA480Hu OneStep ELISA Kit for Myoglobin (MYO) Enzyme-linked immunosorbent assay for Antigen Detection.
SEA480Hu ELISA Kit for Myoglobin (MYO) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA480Hu CLIA Kit for Myoglobin (MYO) Chemiluminescent immunoassay for Antigen Detection.
CMA480Hu Multiplex Assay Kit for Myoglobin (MYO) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
LMA480Hu Multiplex Assay Kit for Myoglobin (MYO) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA480Hu01 ELISA Kit DIY Materials for Myoglobin (MYO) Main materials for "Do It (ELISA Kit) Yourself".