Multiplex Assay Kit for E-selectin ,etc. by CBA (Cytometric Bead Array)

CD62E; CD62-E; E-Selectin; ELAM; ELAM1; ESEL; SEL-E; E-LAM; E-LAM1; E-SEL; LECAM2; Endothelial Leukocyte Adhesion Molecule 1; CD62 Antigen-Like Family Member E

Specificity

This assay has high sensitivity and excellent specificity for detection of E-selectin ,etc. by CBA (Cytometric Bead Array).
No significant cross-reactivity or interference between E-selectin ,etc. by CBA (Cytometric Bead Array) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant E-selectin ,etc. by CBA (Cytometric Bead Array) and the recovery rates were calculated by comparing the measured value to the expected amount of E-selectin ,etc. by CBA (Cytometric Bead Array) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-102 85
EDTA plasma(n=5) 89-96 92
heparin plasma(n=5) 95-102 99

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level E-selectin ,etc. by CBA (Cytometric Bead Array) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level E-selectin ,etc. by CBA (Cytometric Bead Array) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of E-selectin ,etc. by CBA (Cytometric Bead Array) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-94% 90-104% 80-102% 78-93%
EDTA plasma(n=5) 78-90% 80-105% 85-102% 91-98%
heparin plasma(n=5) 80-97% 82-95% 87-102% 78-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity

Assay procedure summary

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Shock Systemic involvement of high-mobility group box 1 protein and therapeutic effect of anti-high-mobility group box 1 protein antibody in a rat model of crush injury. PubMed: 22392147
BioMed research international Endothelial gene expression and molecular changes in response to radiosurgery in in vitro and in vivo models of cerebral arteriovenous malformations Pubmed: 24199192
Journal of Neuroimmunology Evaluation of the effects of Eserine and JWH-133 on brain dysfunction associated with experimental endotoxemia PubMed: 25867462
International Journal of Food Sciences and Nutrition Serum lipid profile and inflammatory markers in the aorta of cholesterol-fed rats supplemented with extra virgin olive oil, sunflower oils and oil-products PubMed: 26401576
Experimental Parasitology Adhesion molecules, chemokines and matrix metallo-proteinases response after albendazole and albendazole plus steroid therapy in swine neurocysticercosis pubmed:28821422
journal of thoracic and cardiovascular surgery Evaluating Platelet Activation Related to the Degradation of Biomaterials Using Molecular Markers Pubmed: 32812629
BMC Endocrine Disorders The role of the adipocytokines vaspin and visfatin in vascular endothelial function and insulin resistance in obese children Pubmed: 31771561
Scientific Reports Association between Upper-airway Surgery and Ameliorative Risk Markers of endothelial function in obstructive Sleep Apnea Pubmed: 31882827
Frontiers in Pharmacology Hyperoside Protects Human Umbilical Vein Endothelial Cells Against Anticardiolipin Antibody-Induced Injury by Activating Autophagy Pubmed: 32508661
Microvasc Res Effect of liraglutide on microcirculation in rat model with absolute insulin deficiency 34119534
Anim Sci J Effect of dipeptide on intestinal peptide transporter 1 gene expression: An evaluation using primary cultured chicken intestinal epithelial cells 34309968
Experimental and Therapeutic Medicine Construction of a rabbit model with vinorelbine administration via peripherally inserted central catheter and dynamic monitoring of changes in phlebitis and thrombosis Pubmed:35126715
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
EPA029Hu61 Eukaryotic E-selectin Positive Control; Immunogen; SDS-PAGE; WB.
RPA029Hu01 Recombinant E-selectin Positive Control; Immunogen; SDS-PAGE; WB.
PAA029Hu01 Polyclonal Antibody to E-selectin WB
MAA029Hu22 Monoclonal Antibody to E-selectin WB; IHC; ICC; IP.
SEA029Hu ELISA Kit for E-selectin Enzyme-linked immunosorbent assay for Antigen Detection.
SCA029Hu CLIA Kit for E-selectin Chemiluminescent immunoassay for Antigen Detection.
LMA029Hu Multiplex Assay Kit for E-selectin ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
CMA029Hu Multiplex Assay Kit for E-selectin ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.