ELISA Kit for Corin (CRN)

ATC2; CRN; Lrp4; TMPRSS10; Atrial Natriuretic Peptide-Converting Enzyme, Serine Protease; Heart-specific serine proteinase ATC2; Pro-ANP-converting enzyme

Specificity

This assay has high sensitivity and excellent specificity for detection of Corin (CRN).
No significant cross-reactivity or interference between Corin (CRN) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Corin (CRN) and the recovery rates were calculated by comparing the measured value to the expected amount of Corin (CRN) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-101 97
EDTA plasma(n=5) 88-95 92
heparin plasma(n=5) 92-101 96

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Corin (CRN) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Corin (CRN) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Corin (CRN) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 85-99% 86-95% 94-102% 96-104%
EDTA plasma(n=5) 90-102% 79-101% 84-91% 98-105%
heparin plasma(n=5) 80-101% 78-96% 97-104% 79-96%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
PLoS One Enhanced heart failure, mortality and renin activation in female mice with experimental dilated cardiomyopathy pubmed:29240788
PLoS One Increases in plasma corin levels following experimental myocardial infarction reflect the severity of ischemic injury Pubmed: 30192780
American Journal of Pathology Placental overexpression of soluble CORIN in preeclampsia Pubmed: 32084366
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPG316Hu02 Recombinant Corin (CRN) Positive Control; Immunogen; SDS-PAGE; WB.
RPG316Hu01 Recombinant Corin (CRN) Positive Control; Immunogen; SDS-PAGE; WB.
RPG316Hu04 Recombinant Corin (CRN) Positive Control; Immunogen; SDS-PAGE; WB.
RPG316Hu03 Recombinant Corin (CRN) Positive Control; Immunogen; SDS-PAGE; WB.
PAG316Hu01 Polyclonal Antibody to Corin (CRN) WB; IHC; ICC; IP.
PAG316Hu04 Polyclonal Antibody to Corin (CRN) WB; IHC; ICC; IP.
PAG316Hu02 Polyclonal Antibody to Corin (CRN) WB; IHC; ICC; IP.
PAG316Hu03 Polyclonal Antibody to Corin (CRN) WB; IHC; ICC; IP.
MAG316Hu21 Monoclonal Antibody to Corin (CRN) WB; IHC; ICC; IP.
SEG316Hu ELISA Kit for Corin (CRN) Enzyme-linked immunosorbent assay for Antigen Detection.
CEG316Hu ELISA Kit for Corin (CRN) Enzyme-linked immunosorbent assay for Antigen Detection.
LMG316Hu Multiplex Assay Kit for Corin (CRN) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.