Packages (Simulation)
Reagent Preparation
Image (I)
Image (II)
Certificate
ELISA Kit for Urocortin 2 (UCN2)
URP; SRP; UCN-II; UCNII; Stresscopin-Related Peptide; Urocortin-related peptide
- Product No.CEC585Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Sample Typeserum, plasma and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range1.23-100ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.44ng/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 479
For more details, please contact local distributors! US$ 684 US$ 3078 US$ 5814 US$ 47880
Specificity
This assay has high sensitivity and excellent specificity for detection of Urocortin 2 (UCN2).
No significant cross-reactivity or interference between Urocortin 2 (UCN2) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Urocortin 2 (UCN2) and the recovery rates were calculated by comparing the measured value to the expected amount of Urocortin 2 (UCN2) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 97-105 | 102 |
EDTA plasma(n=5) | 93-101 | 96 |
heparin plasma(n=5) | 95-103 | 98 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Urocortin 2 (UCN2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Urocortin 2 (UCN2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Urocortin 2 (UCN2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 88-104% | 85-93% | 99-105% | 82-99% |
EDTA plasma(n=5) | 96-104% | 97-105% | 78-104% | 96-104% |
heparin plasma(n=5) | 97-105% | 84-98% | 95-103% | 81-93% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1×120µL | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
TMB Substrate | 1×9mL | Stop Solution | 1×6mL |
Wash Buffer (30 × concentrate) | 1×20mL | Instruction manual | 1 |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
Clin Chem. | High-Sensitivity Sandwich ELISA for Plasma NT-proUcn2: Plasma Concentrations and Relationship to Mortality in Heart Failure. Pubmed:27127183 |
Clinica Chimica Acta | Urocortins: Actions in health and heart failure pubmed:28887029 |
Cardiovascular Research | Urocortin-2 improves right ventricular function and attenuates pulmonary arterial hypertension Pubmed:29584808 |
Journal of Neuroendocrinology | Glucocorticoid withdrawal affects stress‐induced changes in urocortin 2 gene expression in the rat adrenal medulla and brain Pubmed:29604138 |
High Blood Press Cardiovasc Prev | Evaluation of Serum Urocortin 2 Levels in Patients with Hypertension Pubmed: 31925709 |
CURRENT PROBLEMS IN CARDIOLOGY | Urocortin-2 in acute heart failure: role as a marker of volume overload and pulmonary hypertension 33994037 |
Catalog No. | Related products for research use of Mus musculus (Mouse) Organism species | Applications (RESEARCH USE ONLY!) |
RPC585Mu01 | Recombinant Urocortin 2 (UCN2) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPC585Mu02 | Recombinant Urocortin 2 (UCN2) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAC585Mu02 | Polyclonal Antibody to Urocortin 2 (UCN2) | WB; IHC; ICC; IP. |
PAC585Mu01 | Polyclonal Antibody to Urocortin 2 (UCN2) | WB; IHC; ICC; IP. |
SEC585Mu | ELISA Kit for Urocortin 2 (UCN2) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEC585Mu | ELISA Kit for Urocortin 2 (UCN2) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMC585Mu | Multiplex Assay Kit for Urocortin 2 (UCN2) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |