ELISA Kit for Calcitonin (CT)
CALCA; CALC1; CGRP-I; CGRP1; KC; CCP; PDN-21; Katacalcin; Calcitonin-Related Polypeptide Alpha; Calcitonin carboxyl-terminal peptide
- Product No.CEA472Ca
- Organism SpeciesCanis familiaris; Canine (Dog) Same name, Different species.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range12.35-1000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 5.28pg/mL.
- DownloadInstruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- FOB
US$ 504
For more details, please contact local distributors! US$ 720 US$ 3240 US$ 6120 US$ 50400
Specificity
This assay has high sensitivity and excellent specificity for detection of Calcitonin (CT).
No significant cross-reactivity or interference between Calcitonin (CT) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Calcitonin (CT) and the recovery rates were calculated by comparing the measured value to the expected amount of Calcitonin (CT) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 79-95 | 90 |
EDTA plasma(n=5) | 97-105 | 102 |
heparin plasma(n=5) | 93-101 | 97 |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Calcitonin (CT) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Calcitonin (CT) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Calcitonin (CT) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 84-98% | 81-104% | 93-105% | 91-99% |
EDTA plasma(n=5) | 80-93% | 81-94% | 93-101% | 81-89% |
heparin plasma(n=5) | 85-99% | 79-96% | 79-89% | 78-95% |
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents | Quantity | Reagents | Quantity |
Pre-coated, ready to use 96-well strip plate | 1 | Plate sealer for 96 wells | 4 |
Standard | 2 | Standard Diluent | 1×20mL |
Detection Reagent A | 1 | Assay Diluent A | 1×12mL |
Detection Reagent B | 1×120µL | Assay Diluent B | 1×12mL |
Reagent Diluent | 1×300µL | Stop Solution | 1×6mL |
TMB Substrate | 1×9mL | Instruction manual | 1 |
Wash Buffer (30 × concentrate) | 1×20mL |
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
GIVEAWAYS
INCREMENT SERVICES
Magazine | Citations |
indian Journal of Experimental Biology | Effect of consumption of fatty acids, calcium, Vitamin D and boron with regular physical activity on bone mechanical properties and corresponding metabolic hormones in rats Niscair: 13737 |
Toxicol Ind Health | The effect of supplementation of calcium, vitamin D, boron, and increased fluoride intake on bone mechanical properties and metabolic hormones in rat PubMed: 22782709 |
The Journal of Clinical Endocrinology & Metabolism | Interleukin-2 and Lanreotide in the Treatment of Medullary Thyroid Cancer: In Vitro and In Vivo Studies Pubmed: 23884781 |
Academic Journal | Effect of whole body vibration on healthy rat plasma parameters Ebscohost: Source |
Indian Journal of Experimental Biology | Effect of consumption of fatty acids, nutrients and regular physical activity on bone mechanical properties in rats Pubmed:22439438 |
International journal of cardiology | Differences in biochemical and genetic biomarkers in patients with heart failure of various etiologies. pubmed:27448535 |
7 | Cell-matrix signals specify bone endothelial cells during developmental osteogenesis. pubmed:28218908 |
International Journal of Advanced Research in Biological Sciences | Effects of fatty acids, nutrients and whole body vibration on bone histomorphometry, mechanical properties and metabolic parameters in male rat 10.22192/ijarbs.2017.04.04.018 |
cell proliferation | p75NTR−/− mice exhibit an alveolar bone loss phenotype and inhibited PI3K/Akt/β‐catenin pathway Pubmed: 32215984 |
Nature | Paracrine signalling by cardiac calcitonin controls atrial fibrogenesis and arrhythmia Pubmed: 33149301 |
Clin Chim Acta | Copeptin in fluid disorders and stress Pubmed:35143773 |
Catalog No. | Related products for research use of Canis familiaris; Canine (Dog) Organism species | Applications (RESEARCH USE ONLY!) |
RPA472Ca01 | Recombinant Calcitonin (CT) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA472Ca01 | Polyclonal Antibody to Calcitonin (CT) | WB; IHC; ICC; IP. |
MAA472Ca21 | Monoclonal Antibody to Calcitonin (CT) | WB; IHC; ICC; IP. |
CEA472Ca | ELISA Kit for Calcitonin (CT) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA472Ca | Multiplex Assay Kit for Calcitonin (CT) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |