ELISA Kit for Hyaluronan Synthase 1 (HAS1)

HuHAS1; HA synthase 1; Hyaluronate synthase 1; Hyaluronic acid synthase 1

Specificity

This assay has high sensitivity and excellent specificity for detection of Hyaluronan Synthase 1 (HAS1).
No significant cross-reactivity or interference between Hyaluronan Synthase 1 (HAS1) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Hyaluronan Synthase 1 (HAS1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Hyaluronan Synthase 1 (HAS1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Biosensors and Bioelectronics DNA nanotetrahedron-assisted electrochemical aptasensor for cardiac troponin I detection based on the co-catalysis of hybrid nanozyme, natural enzyme and artificial …
Cardiology and Cardiovascular Research Curative and Preventive Treatment for Cardiovascular Disease (CVD) Targeting Multiple Etiology
ACS Appl Mater Interfaces Emitter–Quencher Pair of Single Atomic Co Sites and Monolayer Titanium Carbide MXenes for Luminol Chemiluminescent Reactions 34914377
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC520Hu01 Recombinant Hyaluronan Synthase 1 (HAS1) Positive Control; Immunogen; SDS-PAGE; WB.
PAC520Hu01 Polyclonal Antibody to Hyaluronan Synthase 1 (HAS1) WB; IHC; ICC; IP.
MAC520Hu22 Monoclonal Antibody to Hyaluronan Synthase 1 (HAS1) WB; IHC; ICC; IP.
SEC520Hu ELISA Kit for Hyaluronan Synthase 1 (HAS1) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC520Hu Multiplex Assay Kit for Hyaluronan Synthase 1 (HAS1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.